![IFM OGD25 Series Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/ifm/ogd25-series/ogd25-series_operating-instructions-manual_4048179030.webp)
OGD25x OGD55x
Photoelectric distance sensor
30
u
Use [▲/▼] to select the output configuration [Fno] or [Fnc].
u
Confirm by clicking on [●].
u
Select [SEL1] / [SEL2].
u
Confirm by clicking on [●].
u
Use [▲/▼] to select the measured parameter [diSt] (distance) / [rEFL] (reflectivity).
u
Confirm by clicking on [●].
u
Select [SFx].
u
Confirm by clicking on [●].
w
The set window width is displayed.
u
Keep [▲] or [▼] pressed for at least 3 s.
u
Use [▲/▼] to set the window width.
u
Confirm by clicking on [●].
u
Select [tFOx].
u
Confirm by clicking on [●].
u
Keep [▲] or [▼] pressed for at least 3 s.
w
The current measured value is displayed. The measured value depends on the current situation.
If the current measured value leads to an invalid switch point, this is indicated in the display with
[FAr] / [nEAr].
u
Confirm by clicking on [●].
w
The new measured value flashes once.
w
The taught values are stored in [nSPx] / [FSPx] or [bSPx] / [dSPx].
11.2.5.2 Teaching via IO-Link
u
Call up [Parameter] > [Output configuration].
u
Select the output function [Fno] or [Fnc] under [OU1] / [OU2].
u
Select the measured parameter under [SEL1] / [SEL2].
u
Call up [Parameter] > [Digital output 1 ] / [Digital output 2].
u
Select [Distance] / [Reflectivity].
u
Set the window width under [SFx – DIST] or [SFx – REFL].
u
Click on [Teach tFox].
w
A window with the predefined window width around the switch point is taught.
w
The taught value is stored in [nSPx] / [FSPx] or [bSPx] / [dSPx].
11.3 Extended functions
11.3.1 Operating modes
The device has three operating modes:
•
[Fine]: is optimised with regard to “repeatability” and detecting smallest possible object heights.
•
[Standard]: combines the detection of small object heights with a higher measuring speed.