background image

4

According to cULus

Caution - Use of controls or adjustments or procedures other than those specified 

herein may result in hazardous radiation exposure�

Visible laser light; CLASS 1 LASER PRODUCT� 

EN/IEC 60825-1 : 2007 and EN/IEC 60825-1 : 2014 complies with 21 CFR 

1040 except for deviations pursuant to Laser Notice No� 50, dated June 

2007

Position of the product label

Warning sign

LASER KLASSE 1

CLASS 1 LASER PRODUCT

APPAREIL A LASER CLASSE 1

3  Functions and features

The unit is used as an optical distance sensor�

3.1  Applications

•  The optical distance sensor measures distances between 0�03 and 2 m�
•  It has a background suppression of up to 20 m�
•  The switching outputs are complementary�

The distance between the sensor and the background must be limited 

to max� 20 m by the customer� Otherwise measured values can be 

ambiguous → 4.1 Installation conditions.

Содержание O5D15 Series

Страница 1: ...Operating instructions Optical distance sensor O5D15x UK 80284257 00 04 2019...

Страница 2: ...ation conditions 5 5 Operating and display elements 5 6 Electrical connection 6 7 Settings 7 7 1 The sensor is to switch when the object is detected 7 8 IO Link 7 8 1 General information 7 8 2 Device...

Страница 3: ...the operator the user and if applicable for any service personnel authorised by the manufacturer of the system Read this document before setting up the product and keep it during the entire service l...

Страница 4: ...une 2007 Position of the product label Warning sign LASER KLASSE 1 CLASS 1 LASER PRODUCT APPAREIL A LASER CLASSE 1 3 Functions and features The unit is used as an optical distance sensor 3 1 Applicati...

Страница 5: ...et switch point and a distance of 20 m from the sensor is suppressed Reflecting surfaces in the direct beam path of the sensor also in the range 20 m are to be avoided by the customer Otherwise the me...

Страница 6: ...allation of electrical equipment must be adhered to Ensure voltage supply to EN 50178 Disconnect power Connect the unit as follows DC PNP 4 3 2 1 4 OUT1 normally open IO Link 2 OUT2 normally closed DC...

Страница 7: ...ule IO Link master for operation The IO Link interface enables direct access to the sensor values and parameters and provides the possibility to set the parameters of the unit during operation In addi...

Страница 8: ...normal operating mode Keep pressed until Loc is displayed The unit is locked Unlocking Keep pressed until uLo is displayed The unit is unlocked 9 2 Fault indications Display Possible cause Switching o...

Страница 9: ...of the sensor free from soiling For cleaning do not use any solvents or cleaning agents which could damage the plastic material Do not open the module housing There are no user serviceable components...