17
UK
The capture mode consists of:
• Length of the unambiguous range
•
1 measurement frequency: unambiguous range < "7m"
•
2 measurement frequencies: unambiguous range >= "7m"
• 2 exposure times
• 1 exposure time
7.6.3 Set exposure time
If an "Image Setting Type" is set for 1 exposure time, the following settings are
available:
The single exposure is intended for
scenes with low dynamics�
The exposure time is set in μ
s. The
value is changed with the slider bar
or entered in the box.
If an "Image Setting Type" is set with 2 exposure times, the following settings are
available:
The double exposure is intended for
scenes with high dynamics�
The exposure time is set in μ
s.
The longer exposure time is changed
with the slider bar "Exposure Time" or
entered in the box.
The shorter exposure time is changed
with the slider bar "Exposure Time
Ratio" or entered in the box.