25
3D camera O3X1xx
UK
Parameter name
Data type
Description
Syncing
Bool
Read only: Returns "true" if the system time is
synchronized to a NTP server (i.e. if at least one of
the three most recent synchronization attempts was
successful).
CurrentTime
Int
Read only: Returns the current system time (UTC,
seconds since 1.1.1970).
Stats
String
Read only: Returns a human readable string containg
the synchronization state and accuracy for all
NTP servers.
Default values of Time Config parameters
The default values of the time configuration parameters are:
Parameter name
Data type
Default value
WaitSyncTries
Int
2
SynchronizationActivated
Bool
false
For all other device config parameters there are no defined default values, because they
are either device-dependent (DeviceType, ArticleNumber, ArticleStatus) or volatile (UpTime,
ImageTimestampReference).
Minimum and maximum values of Time Config parameters
The minimum and maximum values of the time configuration parameters are:
Parameter name
Minimum value
Maximum value
WaitSyncTries
1
6
6.8
Application Config Object
save
Method name
save
Description
Stores current configuration in persistent memory.
This is also be possible if the application is not yet in an "activatable"
status.
Input parameters
none
Output parameters
Empty string (compatibility with classic XmlRPC-client)
Validate
Method name
validate
Description
Validates the application. This means it checks if the application can
be activated.
The device should do this check, while activating an application.
Input parameters
none
Output parameters
Array of fault structs (Id: int, Text: string)
Fault scenarios
none
forceTrigger
Method name
forceTrigger
Description
Executes a software trigger of currently active application.
Input parameters
none