10.11 Measuring range
The measuring range
①
isolates the data which is to be used for further calculations . If the measuring
range
①
is set, only the data within the min/max values are used for further calculation . The data outside
the min/max values is abandoned and is available for further functions .
Setting the measuring range
►
Enter min/max values for the coordinate axes .
z
y
x
①
②
②
The measuring range can be displayed and hidden in the monitoring window