11
UK
6.1 Wiring
1
2
(1) Ethernet
M12 socket, D-coded, 4 poles
1 TD +
2 RD +
3 TD -
4 RD -
S screen
(2) Power supply
M12 connector, A-coded, 5 poles
4
2
1
3
5
1 U+
2 trigger input
3 GND
4 switching output 1 - ready
5 switching output 2
Fig� 4: Wiring
6.1.1 Pin 1 (U+) / pin 3 (GND)
The permitted supply voltage is 18���30 V DC�
6.1.2 Pin 2 (trigger input)
The image capture of the device can be triggered with a switching signal via the
trigger input�
The following trigger edges can be used:
• falling edge triggers image capture
• rising edge triggers image capture
• falling and rising edges trigger image capture
• rising edge starts and falling edge ends image capture (gated triggered)� As
long as the trigger is on "high", images are captured with a fixed frame rate�
Further possibilities to trigger the device:
• process interface command