Photoelectric distance sensor
O1D110
17
[nSPx]: switch point "near"
[FSPx]: switch point "far"
FE:
window
If the measured value is etween the switch point “near” [nSPx] and the switch point “far” [FSPx], the
output is opent (if [OUx] = [Fnc]).
Switches when the object is detected
[nSPx]: switch point "near"
[FSPx]: switch point "far"
FE:
window
If the measured value is between the switch point "near” [nSPx] and the switch point "far" [FSPx], the
output is closed (if [OUx] = [Fno]).
Switching state of the outputs
Output function
Object distance (D)
switching status
[Fno]
D < [nSPx]
Open
D > [FSPx]
[nSPx] < D < [FSPx]
Closed
[Fnc]
D < [nSPx]
Closed
D > [FSPx]
[nSPx] < D < [FSPx]
Open
Both window limits([nSPx] and [FSPx]) work with a switching hysteresis.
10.2.7 Setting of the switch points for window function OUT1
u
Under [OU1], select the output function [Fno] or [Fnc].
u
Confirm with [MODE/ENTER].
u
Select [nSP1] and set the switch point “near”.
u
Confirm with [MODE/ENTER].
u
Select [FSP1] nd set the switch point "far".
u
Confirm with [MODE/ENTER].
10.2.8 Configure OUT2
u
Select [OU2].
u
Set switching functions or analogue signals:
•
[Hno] = hysteresis function / normally open