14
10 Technical data
Electrical data
Electrical design
DC PNP
Operating voltage
20�4���26�4 V DC
Rated insulation voltage
32 V DC
Current consumption
< 50 mA
Protection class
III
Reverse polarity protection
yes
Utilisation category
DC12
Operating current
40���700 mA
No-load current
30 mA
Outputs
Voltage drop
1�5 V
Leakage current
0�5 mA
Current rating
50 mA
Short-circuit protection
Yes
Overload protection
Yes
Switching frequency
1 Hz
Max� capacitive load
CL_max
200 nF
Detection zone
Sensing range s
n
(with coded actuator)
12 mm
Safe switch-off distance s
ar
16 mm
Accuracy / deviations
Hysteresis
≤ 20 % S
n
Repeatability
≤ 10 % S
n
Response times
Power-on delay time
1�5s
Response time to safety request
(response time of the semiconductor outputs after the actuator
is moved away > s
ar
)
< 160 ms
Response time when approaching the actuation area
(enable time)
< 600 ms
Risk time (response time for safety-related faults)
< 10 ms