Cylinder sensor with IO-Link
MK59xx
17
u
Move the cylinder to the required end position 1.
ü
Check that the current measured value is within the limits of the measuring range.
u
Select [Parameter] > [Teach].
u
Select [TI Select] and set the switching signal channel [SSC1.x].
w
The following teach will be executed for the selected switching signal channel.
If [TI Select] = [all SSC] is selected, the switch point teach will be carried out for both switching
signal channels simultaneously.
u
Execute command: [Teach SP1].
w
[TI Result. State] shows the status of the teach process.
u
Move the cylinder to the required end position 2.
ü
Check that the current measured value is within the limits of the measuring range.
u
Execute command: [Teach SP2].
w
[TI Result. State] shows the status of the teach process.
w
The switch points SP1 and SP2 are set for the selected switching signal channel.
9.2.2 Section Teach
During [Section Teach], both switch points for the selected switching signal channel SSC1.x are taught
using the current magnet position in an end position and the switch point mode is automatically set to
[Window].
The switch points SP1 and SP2 are calculated with the current measured value and the set hysteresis:
•
SP1 = current measured value - hysteresis
•
SP2 = current measured value + hysteresis
Parameter setting:
u
Install the device in the groove.
u
Select [Parameter] > [Output configuration] > [oux] and set the switching signal channel [SSC1.x].
u
Move the cylinder to the required end position.
ü
Check that the current measured value is within the limits of the measuring range.
u
Select [Parameter] > [Teach].
u
Select [TI Select] and set the switching signal channel [SSC1.x].
w
The following teach will be executed for the selected switching signal channel.
If [TI Select] = [all SSC] is selected, the teach is carried out for both switching signal channels
simultaneously.
u
Select [Parameter] > [SSC1.x] > [SSC1.x Config. Hyst] and set the hysteresis.
u
Select [Parameter] > [Teach] > [Teach Custom].
u
Execute command: [Section Teach].
w
[TI Result. State] shows the status of the teach process.
w
The switch points SP1 and SP2 are set for the selected switching signal channel, the switch point
mode is [Window].