10 Technical data
G2001S
Safety relay with relay outputs
Meets the requirements of:
EN ISO 13849-1 (2008) category 4 PL e, SIL 3 (IEC 61508), SIL
CL
3 (IEC 62061)
Electrical design
relay
Output function
2 safety-related normally open contacts (floating
contacts, 2 A / 250 V);
1 signal output (PNP, 100 mA (24V))
Operating voltage
24 V DC (19�2���28�8)
Contact rating
2 A / 250 V AC / 24 V DC ( ≥ 20 mA)
Short-circuit protection / overload
protection
*) no
Current consumption
208 mA (24 V)
Safety light curtains / light grids to
be connected
1 (with OSSD outputs)
Input muting sensors
2 sensors (24 V DC, PNP, dark-on mode)
Input muting activation
24 V DC, PNP
Output muting lamp
24 V DC / 0,5���5 W
Power-on delay time
< 12 s
Response time on safety request
20 ms
Min� load current of the feedback
contacts
20 mA (24 V)
Current rating auxiliary output
(terminal 21)
max� 100 mA (20 °C)
Ambient temperature
0���55°C
Protection rating
IP 20
Housing materials
PA
Mission Time (TM)
175200 h
Safety-related reliability PFH
7,0
-9
/ h
MTTF
d
100 years
DC / CCF / Cat�
96 % / 80 % / 4
Switching operations
800�000 (2 A (230 V AC) / 0,5 A (24 V DC))
*) The contacts are to be protected by means of fuses with a nominal current of < 3�6 A�