UK
Operating instructions FX460
37
EVENT COLOR 4
Event-dependent colour change of the display for the switching condition of preselection 4, see
Preselection 1 Menu
9.13 Analogue menu
In this menu the basic settings for the analogue output are defined� This function is
only available for the devices DX2022 and DX2032�
ANALOG SOURCE
Source for the analogue output
MEASUREM� RESULT
The measurement result of the selected operating mode is the source�
COUNTER A
The counter reading of channel A is the source�
(Only visible in counter configuration A+B or A-B)�
COUNTER B
The counter reading of channel B is the source�
(Only visible in counter configuration A+B or A-B)�
BATCH COUNTER
The batch counter is the source�
(Only visible in BATCH / TOTAL MODE with INCREMENT BATCH,
DECREMENT BATCH or USE INPUTS ONLY being set)�
TOTAL COUNTER
The total counter is the source�
(Only visible in BATCH / TOTAL MODE with TOTAL COUNTER being
set)�
TOTAL TIMER
The total timer is the source�
(Only visible in TOTAL TIME MODE with YES being set)�
ANALOG FORMAT
This parameter defines the output characteristic� With the output format (-10 … +10 V), the polarity of the
output follows the algebraic sign in the display (only in the COUNTER operating mode)�
The analogue output is proportional to the display value�
-10…10V
-10 … +10 V
0…20MA
0 … 20 mA
4…20MA
4 ��� 20 mA
ANALOG START
With this parameter, the start value of the analogue gain can be set� The start value determines at which
display value the analogue output has a gain of 0 V or 0 / 4 mA�
-99999999
Lowest possible start value
0
Default value
+99999999
Highest possible start value
ANALOG END
With this parameter, the end value of the analogue gain can be set� The end value determines at which
display value the analogue output has a maximum value of +/- 10 V or 20 mA�
-99999999
Lowest possible final value