UK
Operating instructions FX460
21
FACTORY SETTINGS
NO
The factory settings are not loaded
YES
The factory settings are loaded (default values shown in grey)
9.3 Speed mode
In this menu, you can define the operation as rotational speed display (RPM),
tachometer or frequency measurement� In this operating mode, only input A is
active or input A and input B with a phase shift of 90 ° for detection of the direction
of rotation� This menu is only displayed if the corresponding OPERATIONAL
MODE is selected in the GENERAL MENU�
DISPLAY VALUE
Setting of the required value that is to be displayed with the following reference frequency�
1
Lowest value
1000
Default value
99999999
Highest value
BASE FREQUENCY (HZ)
Setting of the reference frequency in Hz for the above display value�
1
Lowest value
100
Default value
500000
Highest value
DECIMAL POINT
This setting defines the position of the decimal point�
NO
No decimal point
0000000�0
Decimal point at the specified position
000000�00
Decimal point at the specified position
00000�000
Decimal point at the specified position
0000�0000
Decimal point at the specified position
000�00000
Decimal point at the specified position
00�000000
Decimal point at the specified position
0�0000000
Decimal point at the specified position
SAMPLING TIME (S)
The set value corresponds to the minimum measured time in seconds� The sampling time serves as a filter
in case of irregular frequencies� This parameter has a direct influence on the response time of the device�
0�005
Minimum measurement time in seconds
0�1
Default value
9�999
Maximum measurement time in seconds