manualshive.com logo in svg
background image

Programming manual 

Supplement

 

Communication between 

multicode reader O2I1xx 

and Siemens Simatic S7 

704546 / 00

  

12 / 2009

UK

Содержание efector 190

Страница 1: ...Programming manual Supplement Communication between multicode reader O2I1xx and Siemens Simatic S7 704546 00 12 2009 UK...

Страница 2: ...parameters on function block FB50 10 3 5 Description function block FB50 10 4 Serial connection via ASCII driver 12 4 1 Principles 12 4 2 Set up of the multicode reader 12 4 3 Set up in step 7 14 4 4...

Страница 3: ...ult Designation of pushbuttons buttons or indications Cross reference Important note Non compliance can result in malfunctions or interference Information Supplementary note General 2 Communication vi...

Страница 4: ...s received byte for byte and stored in the receive buffer For communication via Ethernet all TCP protocol compatible Ethernet CPs can be used However the different selection of the Siemens communicati...

Страница 5: ...UK Communication between multicode reader O2I1xx and Siemens Simatic S7 5 Select Global device settings Network parameters set IP address...

Страница 6: ...Communication between multicode reader O2I1xx and Siemens Simatic S7 6 Select the trigger type Serial in the active configuration...

Страница 7: ...UK Communication between multicode reader O2I1xx and Siemens Simatic S7 7 Set up of the hardware configuration NetPro Step7 3 3 Set up and link the multicode reader as Andere Stationen in NetPro...

Страница 8: ...Communication between multicode reader O2I1xx and Siemens Simatic S7 8 Create TCP connection with multicode reader Note down the connection ID and CP address for the function block parameter setting...

Страница 9: ...UK Communication between multicode reader O2I1xx and Siemens Simatic S7 9 Set the port number as in the parameter setting software...

Страница 10: ...tion block establishes the telegrams to be sent to the multicode reader and creates a character string from the received data flow The trigger input sends a trigger command to the multicode reader wit...

Страница 11: ...flow and then stored consecutively in the receive buffer The length of the receive buffer is defined variably as ANY pointer and can be extended or reduced according to the respective requirements Th...

Страница 12: ...tP CPs with ASCII protocol driver can be used for serial communication In that case however the transmitting and receiving function blocks used in FB49 have to be adapted accordingly The communication...

Страница 13: ...K Communication between multicode reader O2I1xx and Siemens Simatic S7 13 Select Global device settings set transfer parameters here 9600 8N1 Select the trigger type Serial in the active configuration...

Страница 14: ...and Siemens Simatic S7 14 Set up in step 7 4 3 Set up an ASCII coupling for the corresponding CP and define the telegram length 1 byte All other settings depend on the CP used Below as an example the...

Страница 15: ...UK Communication between multicode reader O2I1xx and Siemens Simatic S7 15...

Страница 16: ...Communication between multicode reader O2I1xx and Siemens Simatic S7 16...

Страница 17: ...ome controller types the width of access may not be transmitted correctly in case of symbolic declaration Function block description FB49 4 5 The function block establishes the telegrams to be sent to...

Страница 18: ...receive buffer The length of the receive buffer is defined variably as ANY pointer and can be extended or reduced according to the respective requirements For the serial coupling there is an addition...

Отзывы: