background image

Bedienungsanleitung

Operating instructions

Notice utilisateurs

Elektronischer 

Füllstandssensor

Electronic level sensor 

Détecteur de niveau 

électronique

LK7 / LK0

R

Sachnr

. 701593/07       04/06

DEUTSCH

ENGLISH

FRANÇAIS

Содержание efector 160 LK7

Страница 1: ...enungsanleitung Operating instructions Notice utilisateurs Elektronischer F llstandssensor Electronic level sensor D tecteur de niveau lectronique LK7 LK0 R Sachnr 701593 07 04 06 DEUTSCH ENGLISH FRAN...

Страница 2: ...es page 20 Installation page 21 Electrical connection page 22 Programming page 23 Installation and set up operation page 24 Technical information Functioning Parameters page 24 Adjustable parameters p...

Страница 3: ...eite Page 3 RUN RUN M S M S M M M M S M S S S M M M M M M M S S M M S M S M S M M M S M S S S M M M M M S M M S Men bersicht Menu structure Structure du menu LK7 LK0 Sachnr 701593 06 M S Mode Enter Se...

Страница 4: ...ng auf andere Einheiten und erhalten exakt die gew nschten Werte Decrease the value Let the display of the parameter value move to the maximum setting value Then the cycle starts again at the minimum...

Страница 5: ...instellen der Parameterwerte kontinuierlich durch Dauerdruck schrittweise durch Einzeldruck 1 2 3 4 30 5 64 M12 x1 I L 16 50 51 8 5 A 2 1 3 M LK0022 LK7022 LK0023 LK7023 LK0024 LK7024 L Stabl nge cm i...

Страница 6: ...ng einstellbar Hysteresefunktion Schlie er Hno Hysteresefunktion ffner Hnc Fensterfunktion Schlie er Fno Fensterfunktion ffner Fnc Bestimmungsgem e Verwendung A L I min OFS max min max Me Anzeigewert...

Страница 7: ...die roten LEDs signalisie ren den Schaltzustand der Ausg nge W hrend der Bereitschaftsverz gerungszeit erscheint die Anzeige im Display Anzeige der Parameter und der eingestellten Parameterwerte Das G...

Страница 8: ...er Mitte des Beh lters Bei verschmutzten Medien wird empfohlen Befestigen Sie das Ger t in einer Zone in der das Medium stark in Bewegung ist z B am Zulauf Bei Einbau in metallische Steigrohre Bypass...

Страница 9: ...olgen derma en an Zur sicheren Funktion mu das Sensorgeh use elektrisch mit der Beh lterwand verbunden werden Verwenden Sie dazu den daf r vorgesehenden Geh useanschlu mit blauem Kabelschuh und ein m...

Страница 10: ...V CE Richtlinien Einstellbare Parameter Seite 11 Men struktur Seite 3 Timeout Verriegeln Entriegeln Programmieren 1 Mode Enter Set Mode Enter Set Mode Enter Set Dr cken Sie die Taste Mode Enter bis de...

Страница 11: ...tive Bereich des Sensors mit der Hand oder mit geerde ten Gegenst nden z B einem Schraubenschl ssel ber hrt wurde Nach dem Wechsel von Medien mit stark voneinander abweichen den Dielektrizit tskonstan...

Страница 12: ...zeigeeinheit ein bevor Sie die Schaltgrenzen SPx rPx einstellen Dadurch vermeiden Sie Rundungsfehler bei der internen Umrechnung auf andere Einheiten und erhalten exakt die gew nschten Schaltgrenzen M...

Страница 13: ...it der F llstands nderung mm s LKx022 100 LKx023 200 LKx024 300 DK Medium 2 Max Beh lterdruck bar 0 5 bei Einbau mit ifm Montagezubeh r Geh usewerkstoffe EPDM X Santoprene FPM Viton Messing optalloybe...

Страница 14: ...e H he von SP1 bestimmt bis zu welchem F llstand Max nachge f llt werden soll Das Erreichen des maximalen F llstands wird signali siert durch Verl schen von LED I und Abfall des Signals an Ausgang 1 S...

Страница 15: ...te 15 Hebeanlage DEUTSCH Applikationen L SP2 rP2 1 0 OFS OUT1 Hno 1 0 OUT2 Hnc SP1 rP1 t Anzeigewert Entleeren berf ll sicherung Schaltausgang 1 Regelung Beh lter entleeren Oberer Normalwert berschrit...

Страница 16: ...lstand unterschritten ist berf llung Ausgang 1 zur ckgesetzt AUS und Ausgang 2 zur ckgesetzt AUS Min Wert unterschritten Ausgang 1 hat Signal EIN und Ausgang 2 zur ckgesetzt AUS Seite 16 Vorlage bzw D...

Страница 17: ...Seite 17 DEUTSCH...

Страница 18: ...n setting of the parameter values scrolling by holding pressed incremental by pressing briefly 1 2 3 4 30 5 64 M12 x1 I L 16 50 51 8 5 A 2 1 3 M LK0022 LK7022 LK0023 LK7023 LK0024 LK7024 L probe lengt...

Страница 19: ...n be selected for each output separately hysteresis function N O Hno hysteresis function N C Hnc window function N O Fno window function N C Fnc A L I min OFS max min max LK7024 LK7023 LK7022 LK0024 L...

Страница 20: ...ng state of the outputs During the power on delay time is displayed Indication of parameters and the set parameter values When the Mode Enter button is pressed briefly the unit passes to the Display m...

Страница 21: ...is installed in small plastic tanks For dirty media we recommend Fasten the unit in a zone where there is much movement of the medium e g at the supply inlet When installed in metal rising pipes bypas...

Страница 22: ...using must be electrically connected to the vessel wall To do so use the housing connection with the blue cable lug see scale drawing and a cable piece with a wire cross section of min 1 5mm that is a...

Страница 23: ...MC CE guidelines Adjustable parameters page 24 Programming menu page 3 Timeout Locking Unlocking Programming ENGLISH Electrical connection 1 Mode Enter Set Mode Enter Set Mode Enter Set Press the Mode...

Страница 24: ...the hand or grounded objects e g a screwdriver After a change of media if the dielectric constants differ much e g oil water Programming menu page 3 Page 24 Display during operation Level at power on...

Страница 25: ...inch Select the display unit before setting the switch points SPx rPx This avoids rounding errors generated internally during the conversion of the units and enables exact setting of the values Min Ma...

Страница 26: ...suring range 2 Maximum speed of the change of level mm s LKx022 100 LKx023 200 LKx024 300 Dielectric constant medium 2 Maximum vessel pressure bar 0 5 when mounted with mounting accessories Housing ma...

Страница 27: ...P1 determines up to which level max is to be refilled When the maximum level is reached this is signalled by the LED I going out and output 1 switching off Page 27 Hydraulic vessel Applications ENGLIS...

Страница 28: ...Page 28 Pumping station Applications L SP2 rP2 1 0 OFS OUT1 Hno 1 0 OUT2 Hnc SP1 rP1 t display value empty overflow protection Switching output 1 control to empty vessel upper value exceeded submersi...

Страница 29: ...el is below the minimum level Overflow output 1 switched off and output 2 switched off Below min value output 1 switched on and output 2 switched off Page 29 Storage vessel Applications ENGLISH L SP2...

Страница 30: ...t sur le bouton poussoir et le maintenant appuy pas pas en appuyant sur le bouton poussoir plusieurs fois 1 2 3 4 30 5 64 M12 x1 I L 16 50 51 8 5 A 2 1 3 M LK0022 LK7022 LK0023 LK7023 LK0024 LK7024 L...

Страница 31: ...de commutation les deux sorties peuvent tre r gl es s par ment hyst r sis N O Hno hyst r sis N F Hnc fonction fen tre N O Fno fonction fen tre N F Fnc A L I min OFS max min max valeur mesur e affich...

Страница 32: ...de commutation des sorties Durant le retard la disponibilit l information est affich e Visualisation des param tres et des valeurs de param tre r gl es En appuyant bri vement sur le bouton poussoir Mo...

Страница 33: ...l ap pareil au milieu de la cuve si possible En cas de fluides souill s Fixer l appareil dans une zone o le fluide bouge fortement par ex sur l alimentation En cas de montage dans des tuyaux verticau...

Страница 34: ...nt le bo tier du d tecteur doit tre reli lectriquement la paroi de la cuve Pour ce faire utiliser la cosse de c blage bleue voir sch ma d encom brement et un c ble le plus court possible de section tr...

Страница 35: ...locage D blocage Programmation FRAN AIS Raccordement lectrique 1 Mode Enter Set Mode Enter Set Mode Enter Set Appuyer sur le bouton Mode Enter plusieurs fois jusqu ce que le param tre d sir soit affic...

Страница 36: ...r a t touch e par la main ou des objets mis la terre par ex tournevis Apr s un changement de fluides dont les constantes di lectriques sont tr s diff rentes par ex huile eau Menu page 3 Page 36 Affich...

Страница 37: ...ch Choisir l unit d affichage avant de r gler les seuils SPx rPx Cela vitera les erreurs d arrondi g n r es en interne lors de la conversion des unit s et per mettra de r gler des valeurs exacts M mor...

Страница 38: ...022 100 LKx023 200 LKx024 300 Constante di lectrique fluide 2 Pression max de la cuve bar 0 5 si mont avec les accessoires de montage Bo tier EPDM X Santopr ne FPM Viton laiton recouvert d Optalloy NB...

Страница 39: ...P1 d termine le niveau de remplissage max Lorsque le niveau maximal est atteint la LED I s teint et la sortie 1 est d sactiv e Page 39 Cuve hydraulique Applications FRAN AIS t L SP1 rP1 1 0 OFS OUT1 H...

Страница 40: ...ns L SP2 rP2 1 0 OFS OUT1 Hno 1 0 OUT2 Hnc SP1 rP1 t vider protection contre le d bordement Sortie de commutation 1 r gulation vider une cuve valeur normale sup rieure d pass e pompe submersible EN MA...

Страница 41: ...ent sortie 1 d sactiv e et sortie 2 d sactiv e Au dessous de la valeur min sortie 1 commut e et sortie 2 d sac tiv e Page 41 Cuve de stockage Applications FRAN AIS L SP2 SP1 1 0 OFS OUT1 Hnc 1 0 OUT2...