Input/output functions
Processing input values
326
10.1.1
INPUT
9673
Unit type = function block (FB)
Contained in the library:
ifm_CRnnnn_Vxxyyzz.LIB
Available for the following devices:
- PDM360NG: CR108n, CR9042
Symbol in CoDeSys:
Description
8104
INPUT enables determining the state at the input channels (
data sheet).
The FB provides the current state at the selected channel. The measurement and the output value
results from the operating mode indicated via MODE:
- digital input (lowside)
- digital input (highside)
- analogue input 0...20 mA
- analogue input 0...10 V
- analogue input 0...32 V
- analogue input ratiometric measurement 0...32 V
- analogue input resistance measurement
The analogue values are provided as standardised values.
Parameters of the inputs
9675
Parameter
Data type
Description
ENABLE
BOOL
TRUE:
unit is executed
FALSE:
unit is not executed
> POU inputs and outputs are not active
MODE
INPUT_ANALOG_MODES
mode of the input channel