background image

Installation instructions

Process and dialogue module 

ecomatDisplay

CR1074 

CR1075 

CR1076 

CR1077

80289589 / 00

 

09 / 2020

UK

Содержание ecomatDisplay CR1074

Страница 1: ...Installation instructions Process and dialogue module ecomatDisplay CR1074 CR1075 CR1076 CR1077 80289589 00 09 2020 UK...

Страница 2: ...anel mounting control cabinet installation 10 4 3 2 Installation with installation kit 12 4 3 3 Panel cut out 13 4 3 4 Mounting steps 13 4 4 Surface mounting with RAM mount system 15 4 4 1 Mounting st...

Страница 3: ...epair and disposal 50 8 1 Battery change 50 8 2 Cleaning the display surface 51 8 3 Cleaning the housing surface 52 8 4 Repair 52 8 5 Disposal 52 9 Approvals standards 52 This document is the original...

Страница 4: ...nstructions Reaction result Designation of keys buttons or indications Cross reference Important note Non compliance may result in malfunction or interference Information Supplementary note WARNING Wa...

Страница 5: ...oduct must be suitable for the corresponding applications and environmental conditions without any restrictions Only use the product for its intended purpose 3 Functions and features If the operating...

Страница 6: ...it with supply from SELV PELV according to the technical data even in wet environments even outdoors if necessary with additional UV protection Communication with other system components such as decen...

Страница 7: ...l Ethernet and USB interfaces 3 3 Distinctive features CR1074 CR1075 CR1076 CR1077 Touch screen Freely programmable backlit buttons 6 6 6 6 Navigation keys with button 1 1 1 1 Ethernet interfaces 1 1...

Страница 8: ...e responsibility for the compliance with the requirements concerning mounting of the device in the application with regard to shock vibration acceleration and weight lies with the system creator The u...

Страница 9: ...2 38 1 M5 30 1 1 4 x M5 threaded hole for RAM mount system for the fixing profile of the installation kit 2 Pressure compensation element NOTE The device is equipped with a pressure compensation elem...

Страница 10: ...of the device 4 3 Panel mounting control cabinet installation 4 3 1 Safety instructions for panel mounting control cabinet installation The indications concerning the operating temperature refer to bo...

Страница 11: ...the device in a control cabinet the following requirements concerning fire protection apply If installed according to the information given in 4 3 the device itself complies with the requirements of t...

Страница 12: ...ice lies with the system creator 4 3 2 Installation with installation kit The installation kit enables horizontal vertical or overhead mounting of the device in a panel cut out This type of mounting i...

Страница 13: ...on the back of the device 4 2 1 Locator for mounting accessories Attach damping strips to the device Damping strips Insert the device into the cut out Insert the spacer suitable for the panel thicknes...

Страница 14: ...Use zinc plated screws In very corrosive environments such as extremely salty air use screws with surface finishing on a zinc nickel basis with thick film passivation and sealing 1 2 3 4 5 6 7 A Moun...

Страница 15: ...RAM mount system You will find more information about the available RAM mount components at www ifm com 4 4 1 Mounting steps Screw the mounting plate to the back of the device Usable M5 thread depth...

Страница 16: ...ors Observe the national and international regulations for the installation of electrical equipment Accessible surfaces of the device are insulated from the circuits with basic insulation according to...

Страница 17: ...oard system 5 2 Connection accessories You can find more information about the available accessories at www ifm com 5 3 Connection technology Observe all notes on connection technology Note the device...

Страница 18: ...M cables 30 m ensure appropriate protection against surge e g shielded cables For the Ethernet connection use at least a category 5 cable Cat 5 Audio loudspeaker output floating twisted pair wiring Vi...

Страница 19: ...This may result in audible and visible distortion Minimum operating quality of the display Strong HF sources in the proximity may interfere with the display This may cause interference with the entir...

Страница 20: ...the safe function of the device the housing has to be connected to the body GND of the supply using the shortest possible route Establish the connection between the device and the ground of the vehicl...

Страница 21: ...d connector housings and connect the screen of the Ethernet cable to the connector housing Do not lay the cable in parallel to live cables Interference due to external influence Faulty or insufficient...

Страница 22: ...length B as short as possible and position the USB connector in the immediate vicinity of the dialogue module The length B considerably influences the quality of the USB data transmission Use a connec...

Страница 23: ...liable functioning of the application programs they create If necessary they must additionally carry out an approval by corresponding supervisory and test organisations according to the national regul...

Страница 24: ...uired for programming and set up of the device Programming manual ecomatDisplay Manuals as well as online help CODESYS and ecomatDisplay are available for download on the internet www ifm com 6 5 Func...

Страница 25: ...CR1074 CR1075 CR1076 CR1077 25 NOTE Internal temperature exceeds the permissible value 7 Technical data Malfunction or damage to the device possible Reduce device temperature Take appropriate measures...

Страница 26: ...4 mm 7 diagonal Resolution 800 x 480 pixels Orientation horizontal vertical Surface glass chemically hardened and anti re ective Colours 262144 18 bits Background illumination LED lifetime 70 000 h Br...

Страница 27: ...kg Electrical data Operating voltage 8 16 V DC or 16 32 V DC Reverse polarity protection yes in case of supply via the on board system battery Power consumption VBB30 27 W Current consumption VBB0 5...

Страница 28: ...ure must not exceed 85 C Brightness adaptation light sensor in the front of the device to adapt the brightness of the display and the operating elements Clock battery real time clock RTC battery bu er...

Страница 29: ...a valid for the 24 V system Pulse 4 severity level IV function state A data valid for the 12 V system Additional automotive tests ISO 10605 DIN EN ISO 13766 1 ESD 330 pF 2000 4 kV contact discharge fu...

Страница 30: ...out prior notice 17 09 2020 CR1074 page 5 CR1074 Technical data Control systems Back of the unit 1 2 3 4 1 AMP connector 40 poles 2 Locator for the RAM mount system and mounting frame 3 M12 connector...

Страница 31: ...ted not connected SERVICE1 not connected not connected CAN0_H CAN1_H not connected not connected not connected SERVICE0 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 not connected not...

Страница 32: ...10 153 4 x 92 4 mm 7 diagonal Resolution 800 x 480 pixels Orientation horizontal vertical Surface glass chemically hardened and anti re ective Colours 262144 18 bits Background illumination LED lifeti...

Страница 33: ...98 20 Kbits s 1 Mbit s default 250 Kbits s CANopen CiA DS 301 version 4 2 CiA DS 401 version 1 4 or SAE J1939 or free protocol Raw CAN ETH0 transmission rate 10 100 Mbits s protocols TCP IP UDP Modbus...

Страница 34: ...ure must not exceed 85 C Brightness adaptation light sensor in the front of the device to adapt the brightness of the display and the operating elements Clock battery real time clock RTC battery bu er...

Страница 35: ...ta valid for the 24 V system Pulse 4 severity level IV function state A data valid for the 12 V system Additional automotive tests ISO 10605 DIN EN ISO 13766 1 ESD 330 pF 2000 4 kV contact discharge f...

Страница 36: ...out prior notice 17 09 2020 CR1075 page 5 CR1075 Technical data Control systems Back of the unit 1 2 3 4 1 AMP connector 40 poles 2 Locator for the RAM mount system and mounting frame 3 M12 connector...

Страница 37: ...not connected IFM0 CAN0_L CAN1_L CAN2_L CAN3_L not connected SERVICE1 not connected IFM0 CAN0_H CAN1_H CAN2_H CAN3_H not connected SERVICE0 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 11...

Страница 38: ...10 153 4 x 92 4 mm 7 diagonal Resolution 800 x 480 pixels Orientation horizontal vertical Surface glass chemically hardened and anti re ective Colours 262144 18 bits Background illumination LED lifeti...

Страница 39: ...50 Kbits s CANopen CiA DS 301 version 4 2 CiA DS 401 version 1 4 or SAE J 1939 or free protocol Raw CAN ETH0 1 transmission rate 10 100 Mbits s protocols TCP IP UDP Modbus TCP OPC UA Micro Embedded De...

Страница 40: ...measuring the main board temperature The main board temperature must not exceed 85 C Brightness adaptation light sensor in the front of the device to adapt the brightness of the display and the operat...

Страница 41: ...ta valid for the 24 V system Pulse 4 severity level IV function state A data valid for the 12 V system Additional automotive tests ISO 10605 DIN EN ISO 13766 1 ESD 330 pF 2000 4 kV contact discharge f...

Страница 42: ...CR1076 page 5 CR1076 Technical data Control systems Back of the unit 1 2 3 5 6 4 1 AMP connector 40 poles 2 Locator for the RAM mount system and mounting frame 3 M12 connector 5 poles 4 M12 connector...

Страница 43: ...N3_L IFM1 SERVICE1 VIDEO3_SIGNAL IFM0 CAN0_H CAN1_H CAN2_H CAN3_H IFM1 SERVICE0 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 VIDEO0_GND VIDEO1_GND VIDEO2_GND AUDIO_IN_R AUDIO_GND HEAD...

Страница 44: ...en Touch screen PCAP recognition of up to 10 ngers optimised for operation in wet conditions or with gloves Format 16 10 153 4 x 92 4 mm 7 diagonal Resolution 800 x 480 pixels Orientation horizontal v...

Страница 45: ...AN interface 2 0 A B ISO 11898 20 Kbits s 1 Mbit s default 250 Kbits s CANopen CiA DS 301 version 4 2 CiA DS 401 version 1 4 or SAE J 1939 or free protocol Raw CAN ETH0 1 transmission rate 10 100 Mbit...

Страница 46: ...measuring the main board temperature The main board temperature must not exceed 85 C Brightness adaptation light sensor in the front of the device to adapt the brightness of the display and the operat...

Страница 47: ...ta valid for the 24 V system Pulse 4 severity level IV function state A data valid for the 12 V system Additional automotive tests ISO 10605 DIN EN ISO 13766 1 ESD 330 pF 2000 4 kV contact discharge f...

Страница 48: ...CR1077 page 5 CR1077 Technical data Control systems Back of the unit 1 2 3 5 6 4 1 AMP connector 40 poles 2 Locator for the RAM mount system and mounting frame 3 M12 connector 5 poles 4 M12 connector...

Страница 49: ...N3_L IFM1 SERVICE1 VIDEO3_SIGNAL IFM0 CAN0_H CAN1_H CAN2_H CAN3_H IFM1 SERVICE0 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 VIDEO0_GND VIDEO1_GND VIDEO2_GND AUDIO_IN_R AUDIO_GND HEAD...

Страница 50: ...epair and disposal 8 1 Battery change The battery may only be changed by a qualified person Before changing the battery fully separate the device from supply voltage 1 2 1 service cover 2 battery Repl...

Страница 51: ...data Check sealing areas and sealing for soiling Clean them if necessary Unscrew the service cover until the end stop is reached to restore the protection rating Reset the system time via device set...

Страница 52: ...ust only be repaired by the manufacturer Observe the safety instructions 2 Safety instructions 8 5 Disposal Dispose of used batteries in accordance with the national environmental regulations Do not d...

Отзывы: