1 Safety instructions

The unit described is a subcomponent for integration into a system.

– The system architect is responsible for the safety of the system.

– The system architect undertakes to perform a risk assessment and to create documentation in

accordance with legal and normative requirements to be provided to the operator and user of
the system. This documentation must contain all necessary information and safety instructions
for the operator, the user and, if applicable, for any service personnel authorised by the
architect of the system.

Read this document before setting up the product and keep it during the entire service life.

The product must be suitable for the corresponding applications and environmental conditions
without any restrictions.

Only use the product for its intended purpose (

Ò

 Intended use).

If the operating instructions or the technical data are not adhered to, personal injury and/or damage
to property may occur.

The manufacturer assumes no liability or warranty for any consequences caused by tampering with
the product or incorrect use by the operator.

Installation, electrical connection, set-up, operation and maintenance of the product must be
carried out by qualified personnel authorised by the machine operator.

Protect units and cables against damage.

Содержание EC2061

Страница 1: ...Operating instructions EC2061 EC9203 11471078 00 09 2022 GB...

Страница 2: ...1 Safety instructions 3 2 Preliminary note 4 3 Intended use 5 4 Installation 6 4 1 Mounting surface 6 4 2 Fastening 6 5 Electrical connection 7 6 Operation 8 6 1 Switching characteristics 8 7 Maintena...

Страница 3: ...f the system Read this document before setting up the product and keep it during the entire service life The product must be suitable for the corresponding applications and environmental conditions wi...

Страница 4: ...EC2061 EC9203 4 2 Preliminary note You will find instructions technical data approvals accessories and further information using the QR code on the unit packaging or at www ifm com...

Страница 5: ...nclination sensors are designed for vertical mounting and measure inclination angles around the Z axis They enable precise spatial monitoring of an object and measure its position in relation to the g...

Страница 6: ...t not be exposed to any torsional forces or mechanical stress 4 2 Fastening 4 5 6 3 u Secure the device with an M6 screw through the metal socket provided for this purpose u If necessary use the small...

Страница 7: ...colour Potential Operating voltage black BK OUT L L BN BU BK 8 30 V DC Mass brown BN GND Digital output normally open blue BU EC9203 Designation Pin Potential Operating voltage 1 L 4 3 2 1 L L 1 4 3...

Страница 8: ...horizontal installation position 1 when moving the cable entry from bottom to top Reset point exceeding the switching hysteresis by moving the cable entry from top to bottom off on 6 1 Switching char...

Страница 9: ...case of malfunction u Do not open the housing as the unit does not contain any components which can be maintained by the user The unit must only be repaired by the manufacturer u Clean the device usi...

Отзывы: