background image

Installation instructions

AS-i flat cable splitter

E70354
E70372

11434457 / 00   03 / 2022

GB

Содержание E70354

Страница 1: ...Installation instructions AS i flat cable splitter E70354 E70372 11434457 00 03 2022 GB ...

Страница 2: ...ry note 3 1 1 Symbols used 3 1 2 Warnings used 3 2 Safety instructions 4 3 Intended use 5 4 Installation 6 5 Electrical connection 9 6 Maintenance cleaning repair and disposal 10 6 1 Maintenance 10 6 2 Cleaning the housing surface 10 6 3 Repair 10 6 4 Disposal 10 ...

Страница 3: ...uirement Instructions Reaction result Designation of keys buttons or indications Cross reference Important note Non compliance may result in malfunction or interference Information Supplementary note 1 2 Warnings used ATTENTION Warning of damage to property CAUTION Warning of personal injury w Slight reversible injuries may result WARNING Warning of serious personal injury w Death or serious irrev...

Страница 4: ...before setting up the product and keep it during the entire service life The product must be suitable for the corresponding applications and environmental conditions without any restrictions Only use the product for its intended purpose Intended use If the operating instructions or the technical data are not adhered to personal injury and or damage to property may occur In case of malfunctions of ...

Страница 5: ...litter E70354 E70372 5 3 Intended use The flat cable insulation displacement connector allows tapping the AS i voltage and the external auxiliary voltage via the M12 socket current rating 2 A AS i 2 A AUX Technical data ...

Страница 6: ... vertically so that the coupling nut will not damage the thread u Observe the coding of the M12 cables during installation CAUTION Risk of injury from piercing contacts that are sharp edged due to their function when the device is opened u Take special care during installation AS i 1 1 Step 1 Install lower part u Choose a plane mounting surface u Fix the lower part to the mounting surface at the m...

Страница 7: ...ead of the 24 V flat cable to close the unused cable duct 4 5 Step 3 Fit upper part u Place the upper part u Tighten the fixing screws 4 with 2 5 Nm u Remove protective cap from the M12 socket 5 and manually fix the M12 connector using the coupling nut Tighten until you feel the end stop u Check the torque 1 3 Nm 0 1 Nm at the end stop with a torque wrench and retighten if necessary u Recheck all ...

Страница 8: ...lips 6 Accessories u Provide all outgoing cables AS i flat cables and M12 cable with a suitable strain relief max 1 m behind the cable entry With every additional metre install another strain relief 8 7 Step 5 Replace device Note on replacement Precisely use the pierced points of the AS i flat cable 7 or at least position within the black seal 8 of the device ...

Страница 9: ...echnical data Technical data w Safety guaranteed u Alternatively supply the unit via a limited energy circuit according to IEC 61010 1 or class 2 according to UL1310 The external protection of the AS i currents external auxiliary voltage according to the valid regulations in order to comply with the values of the technical data is the responsibility of the system manufacturer The AS i AUX circuits...

Страница 10: ... cleaning and pressure cleaning observe the conditions of the device s protection rating Technical data Cleaning agents must be compatible with housing materials Technical data and wiring and must not damage them 6 3 Repair u It is not possible to repair the unit 6 4 Disposal u After use dispose of the unit in an environmentally friendly way in accordance with the applicable national regulations ...

Отзывы: