DP2200
Analogue threshold display
26
13 Factory settings
Parameter
Factory settings
User settings
SP1/FH1
Set point OUT1
6.00
rP1/FL1
Reset point OUT1
5.00
A.Trm
Analogue termination OUT2
On
• OFF
• On
ou1
Output function OUT1
Hno
• Hno
• Hnc
• Fno
• Fnc
dS1
Switching delay OUT1
0.0 s
dr1
Switch-off delay OUT1
0.0 s
ScAL
Scaling value
OFF
• OFF
• cccc
• ccc.c
• cc.cc
• c.ccc
C.ASP
Customised analogue start
point
----
C.AEP
Customised analogue end
point
----
C.uni *
Customer-specific unit
mA
coLr
Display: colour setting
rEd
• rEd
• grEn
• r1ou
• G1ou
• r-cF
• G-cF
cFH
Colour change: upper limit
value
20.0
cFL
Colour change: lower limit
value
4.0
diS
Display refresh rate
d2 (200 ms)
• OFF
• d1 (50 ms)
• d2 (200 ms)
• d3 (600 ms)
Lo
Lowest measured input value
----
Hi
Highest measured input value ----
dAP
Damping of the measured an-
alogue value
0.060 s
(= 60 ms)
*) can only be configured via IO-Link and parameter setting software:
Parameters adjustable via IO-Link (