DP2122
Speed monitor
32
13 Factory settings
Parameters
Factory settings
User settings
SSC1.ModE
Switch point mode OUT1
1-p
• 1-P
• and
• 2-P
• OFF
SSC1.LoGc
Switch point logic OUT1
no
• no
• nc
SSC1.SP1
Switch point 1 OUT 1
11
SSC1.SP2
Switch point 2 OUT 1
10
SSC1.HyS
Switch point hysteresis OUT1
10 %
SSC1.dS
Switching delay OUT1
0 s
SSC1.dr
Switch-off delay OUT1
0 s
SSC1.P-n
Output configuration
PnP
• PnP
• NPN
SSC2.ModE
Switch point mode OUT2
1-P
• 1-P
• and
• 2-P
• OFF
SSC2.LoGc
Switch point logic OUT2
no
• no
• nc
SSC2.SP1
Switch point 1 OUT2
22
SSC2.SP2
Switch point 2 OUT2
20
SSC2.HyS
Switch point hysteresis OUT2
10 %
SSC2.dS
Switching delay OUT2
0 s
SSC2.dr
Switch-off delay OUT2
0 s
rES
Factory setting
Lo
Lowest measured input value
----
Hi
Highest measured input value ----
dSt
Startup delay time 0 s
PrSC
(only operating mode 2)
Prescaler
1
ScAL
(only operating mode 1)
Set decimal point
OFF
• OFF
• cccc
• ccc.c
• cc.cc
• c.ccc
C.FEP
(only operating mode 1)
User endpoint for frequency
2000
C.uni
(only operating mode 1)
Customer-specific unit
Unit
coLr
Display: colour setting
rEd
• rEd
• grEn
• r1ou
• G1ou
• r-cF
• G-cF
cFH
Colour change: upper limit
value
11
cFL
Colour change: lower limit
value
10