Speed monitor
DP2122
25
•
[On] = the measured value display is switched on in the operating mode.
Press any button to activate the display for at least 30 s in the switched-off state.
8.6.10 diS.U ─ refresh rate of the displayed measured value
•
[d1] = update of the measured values every 50 ms.
•
[d2] = update of the measured values every 200 ms.
•
[d3] = update of the measured values every 600 ms.
Even with an unsteady frequency, [d1] provides optimum readability.
8.6.11 CMPT ─ indication of the operating mode
Indicates the operating mode:Operating modes (
•
[HZ_M] = DP2122_FREQ (unit of measurement Hz and customer-specific).
•
[rpnM] = DP2122_REVL (unit of measurement rpm).
If the operating mode is changed, the parameters of the unit are reset to the factory settings
with the exception of CMPT.
8.7 Parameters adjustable via IO-Link
The following functions or parameters are only available via IO-Link tools.
8.7.1 C.uni – customer-specific unit
Customer-specific unit with max. 4 characters.
8.7.2 FLASH_ON – activate flashing of the display
Used to identify a unit. Display flashes and shows [dEVC].
8.7.3 FLASH_OFF – deactivate flashing of the display
Deactivates the flashing of the display.
8.7.4 SSC counter – switching counter
Counts the state changes from low to high of the internal detection. Counter values are not saved
permanently.
8.7.5 internal_temperature – operating temperature microcontroller
Reads the data from the internal temperature sensor of the microcontroller.
8.7.6 operation_hours – operating hours
Only counts full operating hours. Operating times of less than one full hour are not saved. Counter
readings are saved permanently.