2 Safety instructions
A qualified electrician must connect the unit� Observe the national and
international regulations for the installation of electrical equipment�
3 Functions and features
The inductive compact speed monitor with IO-Link determines the frequency
[pulses/min] with which the sensor is damped without contact� The device
compares the measured value with the switching thresholds and switches the
outputs according to the configuration� The device can be operated in the IO-Link
mode or in the SIO mode (switching output)�
4 Function diagrams
4.1 Single point mode
Normally open (switch point logic = 1)
SP1: switch-off point
SP1+hyst: switch-on point
The "open" output status indicates that a set rotational speed has not been
reached�
Normally closed (switch point logic = 0)
SP1: switch-on point
SP1+hyst: switch-off point
The "closed" output status indicates that a set rotational speed has not been
reached�