background image

Operating instructions 

AS-i CompactLine module

AC2485 

AC2486 

AC2487

80227841/01     03/2019

UK

1

2

4

3

Содержание CompactLine AC2485

Страница 1: ...Operating instructions AS i CompactLine module AC2485 AC2486 AC2487 80227841 01 03 2019 UK 1 2 4 3 ...

Страница 2: ...on 4 5 Electrical connection 6 5 1 External protective circuitry for inductive loads 6 6 Addressing 6 6 1 Addressing with the AC1154 addressing unit 6 6 2 Infrared addressing 6 7 Pin connection data bits 7 8 Maintenance repair and disposal 8 9 Operating and display elements 9 10 Technical data 9 ...

Страница 3: ... to the relevant regulations and EC directives Improper or non intended use may lead to malfunctions of the unit or to unwanted effects in your application Installation electrical connection set up operation and maintenance of the unit must only be carried out by qualified personnel authorised by the machine operator 3 Functions and features maximum number of modules per master 62 threaded bush st...

Страница 4: ...onto the mounting surface using M4 M5 screws and washers 4 Tightening torque max 1 8 Nm Use stainless steel sleeve E70402 for installation in case of high mechanical stress Connect the plugs of the sensors 5 to the M12 sockets Tightening torque 0 8 1 5 Nm Cover the unused sockets with protective caps E73004 Tightening torque 0 6 0 8 Nm The flat cable end seal E70413 must be used if the module is a...

Страница 5: ...g torque 1 8 Nm 2 M3 5 screws supplied Tightening torque 1 2 1 4 Nm 3 Functional earth springs 4 M4 M5 screw and washer not supplied with the device Tightening torque max 1 8 Nm 5 M12 connector Tightening torque 0 8 1 5 Nm Observe the maximum tightening torque of the connection cable ...

Страница 6: ...a free wheel diode on the load ifm elec tronic offers valve plugs with integrated free wheel diodes 6 Addressing The address is set to 0 at the factory 6 1 Addressing with the AC1154 addressing unit The module can be addressed via the addressing cable E70423 6 2 Infrared addressing The safe AS i module also offers the option of infrared addressing with the addressing unit AC1154 and the addressing...

Страница 7: ...Inputs 1 sensor supply L 2 4 data input 3 sensor supply L 5 functional earth Outputs 3 external voltage AUX 4 switching output 5 functional earth FE 1 2 not connected n c AC2487 4 outputs AS i profile S 7 A 7 extended addressing mode yes Data bit D0 D1 D2 D3 Output 1 2 3 4 Socket O 1 O 2 O 3 O 4 Pin 4 4 4 4 Outputs 3 external voltage AUX 4 switching output 5 functional earth FE 1 2 not connected n...

Страница 8: ... generation version 2 0 the parameter P3 must be 1 and the output bit D3 0 The output bit D3 must not be used If a slave with the ID code A option of extended addressing mode is connected to a master of the first generation version 2 0 an address between 1A and 31A must be assigned to this slave 8 Maintenance repair and disposal The operation of the unit is maintenance free Always exchange the upp...

Страница 9: ...AULT red lights AS i communication error slave does not participate in the normal exchange of data e g slave address 0 LED FAULT red flashes peripheral fault e g sensor supply output over loaded or shorted communication active LED IR addressing infrared receiver Overload and short circuit of the input supply and the outputs are signalled as periph eral fault to the AS i master version 2 1 or highe...