83
ifm
Programming Manual BasicController relay CR0431 v03.03.00
05 / 2018
ifm function elements
ifm function elements for the device CR0431
CAN_REMOTE_REQUEST
7625
Unit type = function block (FB)
Unit is contained in the library
ifm_RawCAN_NT_Vxxyyzz.LIB
Symbol in CODESYS:
>
Description
7627
In order to request a remote message, an according requirement is dispatched via
CAN_REMOTE_REQUEST and the response of the other device is sent back as result.
>
Parameters of the inputs
7628
Parameter
Data type
Description
EXECUTE
BOOL := FALSE
FALSE
TRUE (edge):
execute function element once
otherwise: function element is not active
A function element already started is processed.
CHANNEL
BYTE
CAN interface (1...n) depending on the device
ID
DWORD
Number of the data object identifier:
normal frame (2
11
IDs):
0...2 047 = 0x0000 0000...0x0000 07FF
extended Frame (2
29
IDs):
0...536 870 911 = 0x0000 0000...0x1FFF FFFF
Extended
(optional use of the parameter)
BOOL := FALSE
TRUE:
extended Frame (ID = 0...2
29
-1)
FALSE:
normal Frame (ID = 0...2
11
-1)
>
Parameters of the outputs
7629
Parameter
Data type
Description
DATALENGTHCOUNT
BYTE
= Data Length Count
number of the data bytes received
DATA
ARRAY [0..7] OF BYTE
received data, (1...8 bytes)
RESULT
BYTE
feedback of the function block
(possible messages → following table)
Possible results for RESULT:
Value
dec | hex
Description
0
00
FB is inactive
1
01
function block execution completed without error
5
05
FB is being processed
– still receiving
9
09
CAN is not active
242
F2
Error: setting is not possible
Содержание BasicController CR0431