background image

Operating instructions

Ethernet switch

AL3100

11392991 / 01   06 / 2023

GB

Содержание AL3100

Страница 1: ...Operating instructions Ethernet switch AL3100 11392991 01 06 2023 GB...

Страница 2: ...ion 7 5 1 Overview 7 5 2 Install device 7 6 Electrical connection 8 6 1 Overview 8 6 2 General wiring information 8 6 2 1 Connection technology 8 6 3 Ethernet 9 6 4 Voltage output 9 6 4 1 Derating beh...

Страница 3: ...at documentation ifm com 1 1 Symbols used Requirement Instructions Reaction result Designation of keys buttons or indications Cross reference Important note Non compliance may result in malfunction or...

Страница 4: ...ct of the system Read this document before setting up the product and keep it during the entire service life The product must be suitable for the corresponding applications and environmental condition...

Страница 5: ...3100 5 3 Intended use The device is used for networking of up to 6 Ethernet devices The device is designed for use in PROFINET networks The device is designed for use outside of a control cabinet Perm...

Страница 6: ...iority queues 4 4 2 Profinet The device meets the requirements of PROFINET Conformance Class A CC A Support for LLDP filtering Blocked MAC address 01 80 c2 00 00 0e LLDP Multicast 4 3 Ethernet ports S...

Страница 7: ...e u Disconnect the power of the machine before installation u Use a flat mounting surface for installation u Observe the maximum tightening torque u Fasten the module onto the mounting surface using t...

Страница 8: ...ulation according to EN61010 1 They are designed for network environment 0 according to IEC TR62102 6 2 1 Connection technology The M12 connection parts in the device comply with the ingress resistanc...

Страница 9: ...T This allows another device to be supplied via port power OUT daisy chain Max current of US and UA 16 A each Wiring 2 4 1 3 5 1 24 V DC US 2 GND UA 3 GND US 4 24 V DC UA 5 FE u Optional Connect anoth...

Страница 10: ...d the device via the mounting screw of the upper mounting lug u Connect pin 5 of the port XD1 XD2 via an L coded M12 connector with functional earth 6 6 Voltage supply The device is connected to the s...

Страница 11: ...3100 11 u Optional Connect the device via port XD1 to supply voltage UA with 12 24 V DC 8 32 V SELV according to DIN 60950 u For connection use an L coded M12 connector with at least protection rating...

Страница 12: ...ACT port X1 7 1 1 Voltage supply LED Description Colour State Description US Voltage supply status Green Off No supply voltage is applied or the applied supply voltage is too low On Supply voltage ap...

Страница 13: ...up u Install the device correctly u Establish a correct electrical connection with the device w Once connected to the supply voltage the device will start w The LEDs show the status of the device w T...

Страница 14: ...endly way in accordance with the applicable national regulations 9 1 Cleaning the housing surface Clean the surface of the device when necessary u Disconnect the device from the supply voltage u Clean...

Отзывы: