IO-Link Master with Modbus TCP Interface DataLine 4 Ports IP 65 / IP 66 / IP 67
128
14
Index
A
Access the ifm IoT Core ........................................................................ 58
Accessories ........................................................................................... 80
Acyclic Command Channel ................................................................. 100
Acyclic commands ............................................................................... 103
Additional Codes .................................................................................. 102
Appendix ................................................................................................ 81
Application ............................................................................................. 82
Approvals / tests .................................................................................... 84
C
Cleaning process ................................................................................... 76
Command 0x10 – Set mode ................................................................ 104
Command 0x20 – Set validation ID / data storage.............................. 106
Command 0x30 – Set fail-safe data pattern ........................................ 108
Command 0x40 – Reboot .................................................................... 110
Command 0x50 – Factory Reset ......................................................... 111
Command request .............................................. 104, 106, 108, 110, 111
Command response ........................................... 105, 107, 108, 110, 111
Communication, parameter setting, evaluation ..................................... 11
Configuration ......................................................................................... 24
Configuration Area ................................................................................. 88
Configure IO-Link devices ........................................................ 37, 47, 72
Configure IO-Link ports ......................................................................... 45
Configure IoT interface .......................................................................... 40
Configure the fieldbus interface ............................................................. 44
Connect IO-Link devices for Class A operation .................................... 16
Connect IO-Link devices for Class B operation .................................... 17
Connect the device ................................................................................ 18
Control IO-Link master ....................................................................51, 72
D
Diagnostic data ...................................................................................... 90
Digital inputs .......................................................................................... 12
E
Electrical connection ........................................................................14, 85
Electrical data ........................................................................................ 82
Error codes .......................................................................................... 102
Ethernet interface .................................................................................. 20
Example
Activate security mode .................................................................................. 42
Change name of the IO-Link master ............................................................ 49
Change the parameter value of an IO-Link device....................................... 48
Clone the Data Storage of an IO-Link port ................................................... 46
GET request .................................................................................................. 59
Integrate IO-Link master in a CODESYS project ......................................... 64
POST request ................................................................................................ 61
Publish the temperature to an MQTT broker ................................................ 57
Read process data of an IO-Link device ...................................................... 50
Read several parameter values of the IO-Link master simultaneously ....... 53
Read the parameter value of an IO-Link device ........................................... 47
Request with authentication .......................................................................... 43
reset password .............................................................................................. 43
Subscribe to event......................................................................................... 56
Update firmware ............................................................................................ 52
Explanation of Symbols ........................................................................... 6
F
Factory settings ..................................................................................... 79
Fieldbus
Configure IP settings ..................................................................................... 31
set the length of the process data ................................................................. 32
Firmware
Reboot the device ......................................................................................... 36
Reset device to factory settings .................................................................... 36
First steps .............................................................................................. 38
Function ................................................................................................. 10
G
General .................................................................................................... 7
General functions................................................................................... 39
GET request .......................................................................................... 59
I
ifm IoT Core ...................................................................................38, 112
Info
Show device information ............................................................................... 35
Input Data .............................................................................................. 93
Inputs ..................................................................................................... 83
Inputs / outputs ...................................................................................... 82
Integrate the AL1340 into the Modbus project ...................................... 63
Intended use ............................................................................................ 9
Interfaces ............................................................................................... 83
Internet of Things (IoT) .......................................................................... 11
IO-Link ................................................................................................... 11
IO-Link ports .......................................................................................... 16
Activate data transfer to LR AGENT or LR SMARTOBSERVER ................ 32
Configure operating mode............................................................................. 33
set fail-safe values ......................................................................................... 35
Set the device validation and data storage................................................... 34
IO-Link ports (Class A) .......................................................................... 21
IO-Link supply ........................................................................................ 12
IoT
Configure access rights ................................................................................. 29
Configure IP settings ..................................................................................... 27
Configure security mode ............................................................................... 28
Configure the interface to LR AGENT or LR SMARTOBSERVER .............. 30
IoT Core
Diagnostic codes ........................................................................................... 62
General information ....................................................................................... 58
IoT interface
Configure security mode ............................................................................... 41
IoT port .............................................................................................15, 21
IT safety ................................................................................................... 8
L
LED indicators ....................................................................................... 20
Legal and copyright information .............................................................. 5
LR DEVICE ............................................................................................ 25
M
Maintenance, repair and disposal ......................................................... 76
Mapping
Compact Input Block ..................................................................................... 95
Compact Output Block .................................................................................. 97
diagnostic information ................................................................................... 94
Diagnostics .................................................................................................... 91
digital input data ............................................................................................ 94