IO-Link master with EtherCAT interface DataLine 4 ports IP 65 / IP 66 / IP 67
27
>
9.1.4
IoT: Configuring access rights
34046
The access rights define which instance may read and / or write the parameter data, process data and
event/diagnostic messages.
In order to configure the access rights to the IO-Link master:
►
Select [IoT] menu.
>
The menu page shows the current settings.
►
Set the following parameters as required:
Name
Description
Possible values
[Access Rights]
The access rights to the
parameter data, process data
and the event/diagnostic
messages of the IO-Link master
as well as the connected IO-Link
devices
[Et IoT]*
▪
EtherCAT and IoT Core have read and
write access rights to parameters and
process data
▪
EtherCAT and IoT Core have read
access rights to events/alarms
[Et IoT
(read-only)]
▪
EtherCAT has read and write access
rights to parameters and process data
▪
EtherCAT has read access rights to
events/alarms
▪
IoT Core only has read access rights to
parameters, process data and
events/alarms
[IoT only]
▪
IoT Core has read and write access
rights to parameters and process data
▪
IoT has read access rights to
events/alarms
▪
EtherCAT has no access rights
* ... Factory setting
►
Save changed values on the device.
If in LR DEVICE and EtherCAT projection software the parameter [Access Rights] is =
[Et IoT], the parameter values set in the EtherCAT projection software will always
apply.
If the parameter [Access Rights] in LR DEVICE is = [IoT only], set the parameter [Access
Rights] = [Keep settings] in the EtherCAT projection software.
If the parameter [Access Rigts] in LR DEVICE is = [<Fieldbus> + IoT (read-only)], write access
to the device configuration via LR DEVICE and IoT core services is blocked. To enable write
access again, set the parameter to [<Fieldbus> + IoT] via fieldbus configuration software.
Changes of the parameter [Access Rights] will only be effective after restarting the IO-Link
master (
→
Firmware: Reboot the device
(