Operating Instructions IO-Link Master with PROFINET interface DataLine 4 Ports IP 65 / IP 66 / IP 67 / IP 69K (AL1301)
05 / 2018
Appendix
Technical data
>
13.1.4
Inputs
22820
Inputs
Number of digital inputs
8; (IO-Link Port Class A: 4 x 2)
Switching level high [V]
11...28 DC
Switching level low [V]
0...5 DC
Digital inputs protected against short circuits
yes
>
13.1.5
Outputs
22821
Outputs (digital)
Output function
4; (IO-Link Port Class A: 4 x 1)
Max. current load per output [mA]
200
Short-circuit protection
yes
>
13.1.6
Interfaces
10921
Interfaces
Communication interface
Ethernet; IO-Link
Communication interface
IO-Link; TCP/IP; PROFINET IO
Ethernet
Transmission standard
10Base-T; 100Base-TX
Transmission rate [MBit/s]
10; 100
Protocol
TCP/IP; PROFINET IO
Factory settings
IP address: 0.0.0.0
Subnet mask: 0.0.0.0
Gateway IP address: 0.0.0.0
MAC address: see type label
IO-Link master
Type of transmission
COM 1 / COM 2 / COM 3
IO-Link revision
V1.1
Number of ports Class A
4
IoT interface
Transmission standard
10Base-T; 100Base-TX
Transmission rate [Mbits/s]
10; 100
Protocol
DCP, DCHP, Auto IP
Factory settings
IP address: 169.254.X.X
Subnet mask: 255.255.0.0
Gateway IP address: 0.0.0.0
MAC address: see type label