SmartPLC DataLine with Profinet device interface
44
►
Continue with → step 5
4 Configure the IP parameters automatically
►
Check [Optain IP address autom].
►
Press [Accept] to save the changes.
>
The device tries to obtain IP parameters from a DHCP server.
>
If the IP parameter configuration via DHCP server fails, the device will generate the IP parameters by means of the
Zeroconf protocol.
The automatic configuration of the interface takes approx. 10 seconds.
5 Show the current settings
>
The parameters (→ step 2) show the active IP settings of the Konfigurationsschnittstelle 1.
>
5.3.7
Quick setup: Set the configuration interface 2
42159
Configuration interface 2 (X8) has the same configuration options as configuration interface 1
(X3).
→
Quick setup: Set the Konfigurationsschnittstelle 1
(
To configure configuration interface 2 (X8):
1 Select menu page
►
►
Select tab [Config interface X8].
2 Configure interface
►
Set the interface as required.