Operating instructions
Mechatronic flow sensor
SBx4xx
80288586 / 00
11 / 2019
UK
Страница 1: ...Operating instructions Mechatronic flow sensor SBx4xx 80288586 00 11 2019 UK ...
Страница 2: ...ry note CAUTION Warning of personal injury Slight reversible injuries may result Contents 1 Preliminary note 2 2 Safety instructions 3 3 Functions and features 3 4 Function 4 5 Installation 4 5 1 Installation in case of water containing dirt 6 6 Electrical connection 6 7 Technical data and scale drawings 7 8 Troubleshooting 7 9 Maintenance repair and disposal 8 ...
Страница 3: ...ng applications and environ mental conditions without any restrictions Only use the product for its intended purpose Functions and features Only use the product for permissible media Technical data If the operating instructions or the technical data are not adhered to personal injury and or damage to property may occur The manufacturer assumes no liability or warranty for any consequences caused b...
Страница 4: ...lation or in case of a fault e g housing damage media under high pressure or hot media can leak from the system Ensure that the system is free of pressure during installation Ensure that no media can leak at the mounting location during installation Equip the unit with suitable protection e g cover to avoid haz ard to personnel from leaking media Loosening the socket head screw 1 and moving the pr...
Страница 5: ... sensor s inlet or outlet side are not necessary Avoid major changes of cross section on the inlet side Observe the following minimum distances Distance between the sensor and ferromagnetic materials 30 mm Distance between the sensor and constant alternating fields 500 mm Distance between the sensor axes for side by side installation 50 mm ...
Страница 6: ... also possible 6 Electrical connection The unit must be connected by a qualified electrician The national and international regulations for the installation of electrical equipment must be adhered to Voltage supply according to EN 50178 SELV PELV Disconnect power Connect the unit as follows L L 1 BN 2 WH 3 BU Colours to DIN EN 60947 5 2 BN brown BU blue WH white Information about available plugs a...
Страница 7: ...eshooting If there are dirt particles between the float and the housing the display value of the sensor does not return to zero in case of flow standstill In case of dirt the display value can be up to 30 of the final value of the measuring range Corrective action 9 Maintenance repair and disposal ...
Страница 8: ...tration cleaning may be required Loosen socket head screw 1 in the protective cover 2 and unscrew Unscrew sensor head Remove float 3 and spring 4 Clean the inside of the float spring and housing e g by means of compressed air Before re assembly check O ring 5 for damage If necessary replace and grease After cleaning install components again Tighten sensor head with a tightening torque of 10 Nm To ...
Страница 9: ...9 UK 1 2 3 4 6 7 5 More information at www ifm com ...