10
8 Set-up
8.1 Activate adjustment mode
For easy and reliable installation the sensor can be put in the adjustment mode�
45
0
> 5 s
mm
Signal
Power
This is done by placing a metallic
object directly in front of the sensing
face of the fail-safe sensor (close
range)�
After approx� 5 s the yellow LED
starts to flash: The adjustment mode
is active�
As long as this mode is active the
output stages remain in the safe
state�
close range
enable zone
8.2 Determine the enable zone
If the sensor is in the adjustment mode, the enable zone of the sensor can be
determined by moving the damping element�
45
0
mm
Signal
Power
Signal
Power
Signal
Power
As soon as damping is carried out
in the enable zone, the yellow LED
goes out�
If the target is in the close range or in
the immediate vicinity of the enable
zone, the LED starts to flash again�
close range