Operating instructions 

Compressed air meter

SD2000

11406629 / 

00    10 / 2013

UK

Содержание efector300 SD2000

Страница 1: ...Operating instructions Compressed air meter SD2000 11406629 00 10 2013 UK...

Страница 2: ...toring analogue function 8 4 7 Setting of the standard conditions of the volume flow 8 4 8 Low flow cut off LFC 9 5 Installation 9 5 1 Installation location 9 5 2 Installation conditions 9 5 3 Install...

Страница 3: ...3 Setting of measured value damping 20 9 5 4 Setting of the error behaviour of the outputs 20 9 5 5 Setting of the standard pressure to which the measured and display values for volumetric flow refer...

Страница 4: ...r removing them from the compressed air system that the installation is at a standstill and no pressure is applied Improper or non intended use may lead to malfunctions of the unit or to un wanted eff...

Страница 5: ...th art 3 sec 3 of the Directive 97 23 EC and are designed and manufac tured for stable gases of the fluid group 2 in accordance with sound engineer ing practice 4 Function 4 1 Processing of the measur...

Страница 6: ...very 10 minutes After a power failure this value is available as the current meter reading If a time controlled reset is set the elapsed time of the set reset interval is also stored So the possible d...

Страница 7: ...be provided on output 2 Analogue functions 4 6 4 5 Volumetric flow or temperature monitoring switching function OUTx changes its switching state if it is above or below the set switching limits SPx rP...

Страница 8: ...measured value the output signal is 20 mA 9 Curve of the analogue signal with shifted analogue start point 10 Curve of the analogue signal at factory setting 11 Analogue start point ASP determines at...

Страница 9: ...rved 5 1 Installation location Behind the cold dryer near the load If compressed air is fed into the main pipe through parallel pipes the unit should be mounted in the main pipe Installation after the...

Страница 10: ...g 1 2 pipe length horizontal unit vertical fig 3 5 unit on side pipe length left fig 4 Avoid the installation position in fig 6 unit on side pipe length right If the flow rate is low the specified mea...

Страница 11: ...in 1 Ub Pin 3 Ub Pin 4 OUT1 Switching signal limit values for volumetric flow Switching signal quantity meter reached preset value Pulses 1 pulse every time the defined volumetric flow quantity is rea...

Страница 12: ...last reset in 103 standard cubic metres values 9999 are displayed using the 103 exponential notation LED 5 green current medium temperature in C LED 7 yellow switching status of the corresponding out...

Страница 13: ...M S M M M S M S M S M S M Nm3 min S S Nm3 h S 15s S Nm s 15s S Nm3 15s S Nm3 15s C 15s M M M M M M M S M S M S M S M S S M S M S M M M M Mode Enter Set Nm3 current meter reading in Nm3 Nm3 stored met...

Страница 14: ...ue for volumetric flow or temperature DIn2 Configuration of the input Pin2 for counter reset EF Extended functions opening of menu level 2 HI LO Maximum minimum value memory for volumetric flow FOU1 B...

Страница 15: ...type The catalogue of the available DTM objects the IO Link Device Description IODD and the FDT service program ifm Container can be downloaded at www ifm com Service Download 9 1 General parameter s...

Страница 16: ...IO Link communication is active temporary locking or the sensor is permanently locked via software This locking can only be removed via a parameter setting software Change from menu level 1 to menu l...

Страница 17: ...9 2 2 Settings for limit value monitoring with OUT2 Select Uni and set the unit of measurement 9 5 1 Select SEL2 and set FLOW Select OU2 and set the switching function Hno hysteresis function NO Hnc h...

Страница 18: ...ogram controlled counter reset Select rTo and continue with a or b a Reset the counter manually Press Set until rES T is displayed then briefly press Mode Enter b Enter the value for time controlled r...

Страница 19: ...tric flow Select Uni and set the unit of measurement nm3min volumetric flow quantity in standard cubic metres minute nm3h volumetric flow quantity in standard cubic metres hour nmS current flow veloci...

Страница 20: ...2 switches OFF in case of a fault the analogue signal goes to the lower end stop value 3 5 mA OU output 2 switches irrespective of the error as defined with the parameters The curve of the analogue si...

Страница 21: ...ter briefly For the factory settings please refer to the end of these instructions 12 Factory setting We recommend taking down your own settings in that table before carrying out a reset After reset t...

Страница 22: ...all 4 digits are set As soon as the first digit flashes there are 3 options Briefly press Set 1 x The flashing digit increments 9 is followed by 0 1 2 etc 8 1 2 3 SET pressed 1 x 9 1 2 3 SET pressed 1...

Страница 23: ...to the start value After this release Set briefly and start the setting again 10 Operation Correct operation and compliance with the measurement accuracy can only be ensured if the environmental cond...

Страница 24: ...L Measured value 120 of the final value of the measuring range UL Measured value 20 of the final value of the measuring range temperature Err Flashing error in the measuring probe or measured value 13...

Страница 25: ...S 0 010 ImPR YES OU1 Hno OU2 I SP2 FLOW 280 rP2 FLOW 277 SP2 TEMP 24 0 rP2 TEMP 23 8 ASP FLOW 0 AEP FLOW 700 ASP TEMP 0 0 AEP TEMP 60 0 DIn2 EDG FOU1 OFF FOU2 OFF dAP 0 6 rTo OFF diS d3 Uni nm3h SELd...