15
US
7 Operating and display elements
1 to 8: Indicator LEDs
- LED 1 = current volumetric flow in gallons per minute (gpm)�
- LED 2 = current volumetric flow in gallons per hour (gph)�
- LED 3 = current consumed quantity since the last reset in gallons (gal)�
- LED consumed quantity before the last reset in gallons (gal)�
- LED 4 = current medium temperature in °F.
- LED 5 = consumed quantity in 10
3
gallons�
- LED 6 = not used�
- LED 7, LED 8 = switching state of the corresponding output�
9: Alphanumeric display, 4 digits
- indication of the current volumetric flow (if [SELd] = [FLOW] is set)�
- indication of the meter count (if [SELd] = [TOTL] is set)�
- indication of the current medium temperature (if [SELd] = [TEMP] is set)�
- indication of the parameters and parameter values�
10: Mode/Enter pushbutton
- Selection of the parameters and acknowledgement of the parameter values�
11: Set pushbutton
- Setting of the parameter values (scrolling by holding pressed, incremental by pressing
briefly)�
- Change of the display unit in the normal operating mode (Run mode)�