background image

Operating instructions 

Flow rate meter for gases

SD6101

704845 / 00 

 

  07 / 2010

UK

Содержание efector 300 SD6101

Страница 1: ...Operating instructions Flow rate meter for gases SD6101 704845 00 07 2010 UK...

Страница 2: ...llation 8 5 1 Installation location 8 5 2 Installation conditions 8 5 3 Mounting position 9 5 4 Installation in pipes 10 6 Electrical connection 10 7 Operating and display elements 11 8 Menu 12 8 1 Me...

Страница 3: ...he error behaviour of OUT1 OUT2 17 9 4 5 Selection of the medium to be monitored 18 9 5 Service Funktionen 18 9 5 1 Reading the min max values for volumetric flow 18 9 5 2 Reset all parameters to the...

Страница 4: ...at a standstill and no pressure is applied before mounting components into or removing them from compressed air equipment Improper or non intended use may lead to malfunctions of the unit or to unwan...

Страница 5: ...switching signal for volumetric flow limit values 9 2 1 or pulse sequence for totalising meter 9 3 1 or switching signal for preset counter 9 3 2 OUT2 2 selection options switching signal for volumet...

Страница 6: ...x ImPR no rTo time t If the quantity x is reached during the time t output 1 switches and remains switched until the meter is reset If the quantity x has not been reached after the time t the meter is...

Страница 7: ...set points have a fixed hysteresis of 0 25 of the final value of the measuring range This keeps the switching state of the output stable if the volumetric flow varies slightly 4 6 Volumetric flow moni...

Страница 8: ...tion location Behind the cold dryer near the load If compressed air is fed into the main pipe through parallel pipes the unit should be mounted in the main pipe Installation after the maintenance unit...

Страница 9: ...o 90 elbows two planes B 15 x pipe diameter valve slide B 35 x pipe diameter 5 3 Mounting position Permitted mounting positions pipe length vertical any position fig 1 2 pipe length horizontal unit ve...

Страница 10: ...regulations for the installation of electrical equipment must be adhered to Voltage supply to EN50178 SELV PELV Disconnect power Connect the unit as follows 2 switching outputs 1 switching output 1 an...

Страница 11: ...3 and 5 flashing consumed quantity before the last reset in 103 standard cubic feet LED 4 current medium temperature in F LED 6 not used LED 7 LED 8 switching state of the corresponding output 9 Alph...

Страница 12: ...12 8 Menu 8 1 Menu structure Mode Enter Set Nm3 current meter count in standard m3 Nm3 stored meter count in standard m3...

Страница 13: ...mA SP2 rP2 Maximum minimum value for volumetric flow at which OUT2 changes its switching status ASP Analogue start value for volumetric flow AEP Analogue end value for volumetric flow EF Extended func...

Страница 14: ...eter flashes for 5 s After 5 s The setting value is changed incremental by press ing briefly or scrolling by holding pressed Numerical values are incremented continuously If the value is to be reduced...

Страница 15: ...alues Press Mode Enter Set for 10 s uLoc is displayed When delivered unlocked Time out If during parameter setting no pushbutton is pressed for 15 s the unit exits the param eter setting mode The para...

Страница 16: ...quantity monitoring by pulse output Select OU1 and set ImP Select ImPS and set the volumetric flow quantity at which 1 pulse is provided 9 6 Select ImPR and set YES Pulse repetition is active Output...

Страница 17: ...he update rate and orientation of the display d1 update of the measured values every 50 ms d2 update of the measured values every 200 ms d3 update of the measured values every 600 ms rd1 rd2 rd3 displ...

Страница 18: ...flow Select HI or LO and press Set briefly HI maximum value LO minimum value Delete memory Select HI or LO Press Set and keep it pressed until is displayed Press Mode Enter briefly It makes sense to d...

Страница 19: ...4 000 000 scf Setting operation Ensure that OU1 is set to ImP Select ImPS press Set and keep it pressed The current numerical value flashes for 5 s then one of the 4 digits becomes active digit flashe...

Страница 20: ...h digit flashes unchanged for 3 s digit 1 becomes active again if the value of digit 1 is 0 8 1 2 3 no pushbutton pressed after 3 s 8 1 2 3 after 3 s 8 1 2 3 after 3 s 8 1 2 3 after 3 s 8 1 2 3 If dig...

Страница 21: ...utput the output signal is at the maxi mum value during the power on delay time 10 1 Read the set parameters Press Mode Enter until the requested parameter is displayed Press Set briefly The unit disp...

Страница 22: ...rom time to time check the measuring probes visually for build up If necessary clean them at regular intervals To do so use a suitable cleaning liquid e g alcoholic solution Avoid mechanical damage to...

Страница 23: ...asuring range Ar 13 9 15 4174 0 23 0 2 69 6 CO2 8 4 10 2532 0 14 0 1 42 2 N2 10 3 10 2579 0 14 0 1 43 0 Display range Ar 0 5009 0 83 5 CO2 0 3038 0 50 6 N2 0 3094 0 51 6 in brackets displayed value Me...

Страница 24: ...ESD 4 8 KV IEC 1000 4 3 HF radiated 10 V m IEC 1000 4 4 Burst 2 KV IEC 1000 4 6 HF conducted 10 V All data refer to standard volume flow according to DIN ISO 2533 12 1 Setting ranges SCFH SP1 SP2 rP1...

Страница 25: ...tting Factory setting User setting SP1 835 rP1 815 ImPS 0 04 ImPR YES OU1 Hno OU2 Hno SP2 1670 rP2 1650 ASP 0 AEP 4175 FOU1 OFF FOU2 OFF dAP 0 6 rTo OFF diS d3 Uni SCFH SELd FLOW MEDI Ar More informat...

Отзывы: