IFM Electronic efector 200 O5D15 Series Скачать руководство пользователя страница 1

Operating instructions 

Optical distance sensor

O5D15x 

UK

706307 / 01

 

 08 / 2014

Содержание efector 200 O5D15 Series

Страница 1: ...Operating instructions Optical distance sensor O5D15x UK 706307 01 08 2014 ...

Страница 2: ...lation conditions 5 5 Operating and display elements 5 6 Electrical connection 6 7 Settings 7 7 1 The sensor is to switch when the object is detected 7 8 IO Link 7 8 1 General information 7 8 2 Device specific information 7 8 3 Parameter setting tools 7 9 Operation 8 9 1 Electronic lock 8 9 2 Fault indications 8 10 Maintenance repair and disposal 9 ...

Страница 3: ...se may lead to malfunctions of the unit or to unwanted effects in your application That is why installation electrical con nection set up operation and maintenance of the unit must be carried out by qualified personnel authorised by the machine operator In case of malfunction of the unit please contact the manufacturer If the unit is tampered with and or modified any liability and warranty is excl...

Страница 4: ...sition of the product label Warning sign LASER KLASSE 1 CLASS 1 LASER PRODUCT APPAREIL A LASER CLASSE 1 3 Functions and features The unit is used as an optical distance sensor 3 1 Applications The optical distance sensor measures distances between 0 03 and 2 m It has a background suppression of up to 20 m The switching outputs are complementary The distance between the sensor and the background mu...

Страница 5: ...set switch point and a distance of 20 m from the sensor is suppressed Reflecting surfaces in the direct beam path of the sensor also in the range 20 m are to be avoided by the customer Otherwise the meas ured values can be ambiguous 5 Operating and display elements 1 LED green operation 2 LED yellow switching status 3 3 digit alphanumeric display 4 Range 5 Range ...

Страница 6: ...allation of electri cal equipment must be adhered to Ensure voltage supply to EN 50178 Disconnect power Connect the unit as follows DC PNP 4 3 2 1 4 OUT1 normally open IO Link 2 OUT2 normally closed DC NPN 4 3 2 1 4 OUT1 normally open IO Link 2 OUT2 normally closed Core colours of ifm sockets 1 BN brown 2 WH white 3 BU blue 4 BK black ...

Страница 7: ...The IO Link interface enables direct access to the sensor values and parameters and provides the possibility to set the parameters of the unit during operation In addition communication is possible via a point to point connection with a USB adapter cable You will find more detailed information about IO Link at www ifm com uk io link 8 2 Device specific information You will find the IODDs necessary...

Страница 8: ... normal operating mode Keep pressed until Loc is displayed The unit is locked Unlocking Keep pressed until uLo is displayed The unit is unlocked 9 2 Fault indications Display Possible cause Switching output Hno Hnc Too much light e g reflective surfaces ON OFF Not enough light no object OFF ON nEA Object to be measured outside the measuring range 30 mm ON OFF FAr Object to be measured outside the ...

Страница 9: ... of the sensor free from soiling For cleaning do not use any solvents or cleaning agents which could damage the plastic material Do not open the module housing There are no user serviceable components inside Technical data and further information at www ifm com ...