IFM Electronic Efector 100 GM505S Скачать руководство пользователя страница 1

Original operating instructions 

Fail-safe inductive sensor

GM505S

701832 / 03     06 / 2010

UK

Содержание Efector 100 GM505S

Страница 1: ...Original operating instructions Fail safe inductive sensor GM505S 701832 03 06 2010 UK ...

Страница 2: ...8 6 2 Installation conditions 9 7 Electrical connection 9 8 Set up 10 8 1 Activate adjustment mode 10 8 2 Determine the enable zone 11 8 3 End adjustment mode 11 9 Operation 12 9 1 Sensor signals 12 9 2 Input characteristics output characteristics 12 9 3 Cross faults 13 9 4 Operating mode 13 9 4 1 Delayed switching of the LED 13 9 4 2 Switching of the LED without delay 14 9 5 Response times 15 9 6...

Страница 3: ...structions contain information about the correct handling of the product Read the instructions before use to familiarise yourself with operating conditions installation and operation Adhere to the safety instructions 1 1 Explanation of symbols Request for action LED on LED off LED flashes LED flashes quickly Important note 14 Approvals standards 20 15 Terms and abbreviations 21 ...

Страница 4: ... the unit please contact the manufacturer Tampering with the unit is not allowed Disconnect the unit externally before handling it Also disconnect any independently supplied relay load circuits After setup the system has to be subjected to a complete function check Only use the unit under the specified operating conditions 11 Technical data In case of special operating conditions please contact th...

Страница 5: ...ssing or damaged please contact one of the ifm branch offices 4 Functions and features The fail safe inductive sensor detects metal without contact Safety function SF the safe state output stage switched off logic 0 is achieved when undamping greater than or equal to the safe switch off distance sar 11 Technical data Also observe the notes on installation of the sensor 6 Installation The fail safe...

Страница 6: ...lation to IEC 60947 5 2 the enable zone is in the range of 10 20 mm The safe switch off distance sar is 35 mm The enable zone is different if damping elements which deviate from the standard target plate in terms of material form and size are used Enable zone for other materials Material Enable zone steel FE360 10 20 mm stainless steel 7 5 15 mm AIMg3G22 2 7 8 5 mm AI 99 1 9 7 9mm CuZn37 2 9 8 5 m...

Страница 7: ...roducing a metallic object into the enable zone the output is immediately switched but displayed by the signal LED with a delay of about 3 s 9 4 1 Delayed switching of the LED By doing so the object is generally in the close range before the LED indication is lit The technical instructions concerning the restart of the installation must be observed 2 If the object stays in the close range for long...

Страница 8: ...8 6 Installation 6 1 Alignment of the sensing face 2 3 1 5 6 4 The socket is rotatable 8 9 7 ...

Страница 9: ...here to the installation conditions in accordance with the figures 1 to 4 1 80 80 105 2 105 20 105 3 280 4 80 7 Electrical connection Wiring diagram 11 Technical data Disconnect the unit Also disconnect any independently supplied relay load circuits Supply voltage connect L to pin 1 and L to pin 3 of the connector The nominal voltage is 24 V DC This voltage may vary between 19 2 V and 30 V incl 5 ...

Страница 10: ...3 1 24 0 20 2 22 0 32 3 20 0 52 5 18 0 82 7 16 1 3 10 8 Set up 8 1 Activate adjustment mode For easy and reliable installation the sensor can be put in the adjustment mode 35 0 5 s mm Signal Power This is done by placing a metallic object directly in front of the sensing face of the fail safe sensor close range After approx 5 s the yellow signal LED starts to flash the adjustment mode is active As...

Страница 11: ...ed out in the enable zone the yellow LED goes out If the target is in the close range or in the immediate vicinity of the enable zone the LED starts to flash again Close range Enable zone 8 3 End adjustment mode 35 0 2 s mm Signal Power 2 s Signal Power If the sensor is undamped for more than 2 s 35 mm the adjustment mode is switched off and the yellow LED goes out This can also be achieved by pow...

Страница 12: ...131 2 nominal current 0 1 A and nominal voltage 24 V Logic 1 11 V 30 V Input current approx 3 mA Logic 0 5 V Leakage current 500 µA Permissible test pulse duration 1 0 ms If the target is in the enable zone and there is no sensor fault the clock input signal is transferred to the output with the delay td The output characteristics are compatible with the input characteristics to EN 61131 2 type 1 ...

Страница 13: ...yellow LED goes out without delay In case of damping in the close range the output switches off immediately whereas the yellow LED goes out with a delay of approx 2 s With the deactivation of the LED the output is maintained in the safe state logic 0 Thus switching on again in the enable zone is not possible Enabling is done by undamping 35 mm of more than 2 s or by interrupting the voltage 5 2 Pr...

Страница 14: ...t delay Undamping 2s 35 0 0 s mm Signal Power If the target was away from the sensor for less than 2 s 35 mm the yellow LED comes on without delay in case of damping in the enable zone Close range Enable zone except for the first start up ...

Страница 15: ...s Response time for enabling to rising edge of TE damped in the enable zone typ max 40 ms 100 ms Response time risk time for safety related faults T Permissible dwell time in the close range approx 2 s Time delay for activation of the adjustment mode 8 1 Activate adjustment mode approx 5 s Dwell time in the undamped condition 35 mm to return into the operating mode 8 3 End adjustment mode approx 2...

Страница 16: ...ower Output switched off safe state target outside the enable zone operating mode or target in the enable zone adjustment mode Signal Power Output switched target in the enable zone operating mode Signal Power Output switched off safe state target outside the enable zone adjustment mode Signal Power Internal or external fault 12 Troubleshooting ...

Страница 17: ...ical data GM505S GIMC 4035 US Rectangular plastic M12 connector Enable zone 10 20 mm Conforms to the requirements of EN ISO 13849 1 2008 category 4 PL e SIL 3 IEC 61508 Operating voltage 24 V DC 19 2 30 V Short circuit protection yes Reverse polarity protection yes Current consumption 15 mA Rated insulation voltage 30 V ...

Страница 18: ...47 5 2 Application class C to EN 60654 1 weatherproof application Climate Ambient temperature 25 70 C 10 40 C Relative air humidity 5 95 5 70 Rate of temperature change 0 5 K min Air pressure 80 106 kPa Mission time TM Mission time max 87600 h 10 years max 175200 h 20 years Safety related reliability PFH PFHD 1 1 x 10 9 h MTTFD 2500 years DC CCF Cat 99 65 4 Protection IP 67 to EN 60529 III Housing...

Страница 19: ... BU blue WH white The core colours BN BK BU WH apply to the use of ifm sockets Remarks Mission time TM 10 years Mission time TM 20 years Unless stated otherwise all data refer to the 60 x 60 x 1 mm reference target plate to IEC 60947 5 2 FE360 mild steel over the whole temperature range ...

Страница 20: ... repair measures are necessary Only the manufacturer is allowed to repair the unit After use dispose of the unit in an environmentally friendly way in accordance with the applicable national regulations 14 Approvals standards The following standards and directives have been applied 2006 42 EC European machinery directive 2004 108 EC EMC Directive DIN EN 954 1 1996 category 4 safety of machinery sa...

Страница 21: ... their resistance to failures CCF Common Cause Failure DC Diagnostic Coverage MTTFD Mean Time To Dangerous Failure PFH PFHD Probability of dangerous Failure per Hour PL Performance Level PL to EN ISO 13849 1 SIL Safety Integrity Level SIL 1 4 to IEC 61508 PLC Programmable Logic Controller TM Mission Time maximum service life ...