Device manual CR3105/CR3106
40
9 Technical data
9.1 CR3105
remote diagnosis, maintenance and parameter setting
of CAN control systems for mobile applications
aluminium
128 x 85 x 35 mm
with brackets
(prepared mounting holes on the sides, see mounting variants)
IP 65
-30...65 °C
-40...80 °C
290 g
10...30 V DC
95 mA (standard operation), 170 mA (transmission)
2 W
850/900/1800/1900 MHz
max. 9,600 bits/s (real value depends on the network provider)
89/336/EC
CAN interface 2.0 B, ISO 11898
M12 plug for operating voltage and CAN bus, 5 pins (type Lumberg)
CAN electrically separated
20 Kbits/s...1 Mbit/s (default setting 125 Kbits/s)
CANopen, CiA DS 301 version 3.0
hex 1D (= 29 dec)
RS-232, 9-pole Sub-D plug (pin)
type SMA connector (adapter SMA/FME enclosed)
GSM 850/900/1800/1900
text mode
max. 160 characters (corresp. to 7 bits/character)
max. 16 Kbytes
V.42 data compression RLP
Control systems
\DA
TEN\100\DB-FORM—PZD/03/12/96
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen
17.09.2014
CR3105
CANremote
GSM quad-band modem
for the transfer of
SMS messages
and data packets
CAN gateway
with CANopen interface
Operating voltage
10...30 V DC
We reserve the right to make technical alterations without prior notice!
CR3105 / page 1
Application
Mechanical data
Housing
Dimensions (W x H x D)
Installation
Protection rating
Operating temperature
Storage temperature
Weight
Electrical data
Operating voltage
Current consumption (at 24 V DC)
Transmitter power
Frequency band
Transmission rate
EMC
Interfaces
CAN interface
Baud rate
Communication profile
Node ID (default)
Serial interface
Antenna terminals
GSM modem
GSM profile
SMS class (Short Message Service)
SMS character length
Size of data packet
Safety
1) SMA antenna connector
2) CANopen interface
3) Lid
4) SIM card
5) RS-232 interface