8.5.1 Requirements for real-time access with CoDeSys
Real-time access with CoDeSys is only possible if the test pin of the
controller is connected to the operating voltage and the debug mode is
active.(System manual on the controller → Chapter 6, DEBUG mode)
Real-time access is supported for targets from version 5b�
►
Configure the device with the software tool "CANremote_Configurator"� As an
alternative, switch the device to the real-time mode via the application program
(library IFM_CANx_CR310x_Vxxxxxx�lib)�
►
Install the add-on tool "CANremote_Client"�
www.ifm.com → Service → Download
►
Specify the communication channel in CoDeSys� To do so, select
[Communication Parameters] in the menu "Online"�
Open the window "Communication Parameters: New Channel" with [New ���],
enter the name "CANremote" and acknowledge with [OK]�
Specify the communication channel in CoDeSys