background image

47 

ifm

 Operating Instructions IO-Link Master with EtherNet/IP interface StandardLine 8 Ports IP 65 / IP 67 (AL1122) 

2017-05-31 

Configuration 

 

 

 

8.5

 

EtherNet/IP: Configure IO-Link devices 

23106 

The AL1122 supports the configuration of the connected IO-Link devices from the EtherNet/IP 
projection software. For this, ifm offers the EtherNet/IP object "IO-Link Request" (

→ 

IO-Link requests 

(object class: 0x80)

 (

→ p. 

97

)). The object enables direct read and write access to IO-Link objects of the 

IO-Link device. The extent of the configurable parameters depends on the IO-Link device. 

The following services are available: 

Name 

Description 

Reference 

Read request 

Send a request to read an IO-Link object 

→ 

Read_ISDU

 (

→ p. 

98

) 

Write request 

Send a request to write an IO-Link object 

→ 

Write_ISDU

 (

→ p. 

101

) 

  

 

Information for the execution of acyclic commands: 

→ 

Execute acyclic commands

 (

→ p. 

49

) 

Available parameters of the IO-Link devices: 

→   Operating instructions of the IO-Link device 

  

 

8.6

 

EtherNet/IP: Programmers' notes 

23323 

The programmer can access the following data from the PLC application: 

 

Read cyclic input and output data of the IO-Link devices 

 

Read diagnostic and status information 

 

Change parameters of the IO-Link port of the AL1122 

 

Read and change parameters of the connected IO-Link devices 

  

The following sections show the available options. 

 

8.6.1

 

Read cyclic input data 

8518 

The user can access the cyclic input data of the connected sensors and IO-Link devices via the 
controller tags of the AL1122. 

To access the input data: 
► 

Starting RSLogix5000. 

► 

Open a EtherNet/IP project. 

► 

In the project tree: Mouse click on [Controller Tags] > [AL1122.I] 

>

 

The window shows the data structure with cyclic input data ([AL1122.I:Data]) 

  

 

Mapping of the inputs on the data structure [AL1122.I:Data]: 

→ 

Input assembly

 (

→ p. 

72

)) 

  

Содержание AL1122

Страница 1: ...ating Instructions IO Link Master with EtherNet IP interface StandardLine 8 Ports IP 65 IP 67 AL1122 ifm firmware 1 1 22 or higher LR DEVICE 1 1 0 87 or higher IO Link 1 1 2 English 7391102_00_UK 2017 05 31 ...

Страница 2: ... the unit 10 3 Functions and features 11 3 1 Permitted use 11 3 2 Prohibited use 11 4 Function 12 4 1 Communication parameter setting evaluation 13 4 1 1 IO Link 14 4 1 2 EtherNet IP 14 4 1 3 Parameter setting 14 4 1 4 Visual indication 14 4 2 Digital inputs 15 4 3 IO Link supply 15 5 Mounting 16 5 1 Mount the device 16 6 Electrical connection 17 6 1 Ethernet ports 18 6 2 IO Link ports 19 6 2 1 In...

Страница 3: ... the EDS file 43 8 4 2 Integrate the AL1122 into the EtherNet IP network 43 8 4 3 Configure AL1122 44 8 4 4 Configure IO Link ports 45 8 5 EtherNet IP Configure IO Link devices 47 8 6 EtherNet IP Programmers notes 47 8 6 1 Read cyclic input data 47 8 6 2 Write cyclic output data 48 8 6 3 Execute acyclic commands 49 8 6 4 Read diagnostic and status information 51 9 Operation 52 9 1 Read device info...

Страница 4: ...erNet IP interface StandardLine 8 Ports IP 65 IP 67 AL1122 2017 05 31 Preliminary note 12 2 EtherNet IP 66 12 2 1 Parameter data 67 12 2 2 Cyclic data 71 12 2 3 Acyclic data 77 13 Index 109 14 ifm weltweit ifm worldwide ifm à l échelle internationale 111 ...

Страница 5: ...k Master with EtherNet IP interface StandardLine 8 Ports IP 65 IP 67 AL1122 2017 05 31 Preliminary note 1 Preliminary note Legal and copyright information 6 Purpose of the document 6 Symbols and styles used 6 Modification history 7 14801 ...

Страница 6: ...eckhoff Automation GmbH Germany IO Link www io link com is the property of the PROFIBUS Nutzerorganisation e V Germany ISOBUS is the property of the AEF Agricultural Industry Electronics Foundation e V Deutschland www aef online org Microsoft is the property of the Microsoft Corporation USA www microsoft com PROFIBUS is the property of the PROFIBUS Nutzerorganisation e V Germany www profibus com P...

Страница 7: ...ng Instructions IO Link Master with EtherNet IP interface StandardLine 8 Ports IP 65 IP 67 AL1122 2017 05 31 Preliminary note 1 4 Modification history 21676 Version Topic Date 00 New creation of document 30 05 2017 ...

Страница 8: ...er with EtherNet IP interface StandardLine 8 Ports IP 65 IP 67 AL1122 2017 05 31 Safety instructions 2 Safety instructions General 9 Required background knowledge 9 Warnings used 9 Safety symbols on the device 10 Tampering with the unit 10 213 ...

Страница 9: ... operators and machinery Observe these operating instructions Adhere to the warning notes on the product 2 2 Required background knowledge 22046 This document is intended for specialists Specialists are people who based on their relevant training and experience are capable of identifying risks and avoiding potential hazards that may be caused during operation or maintenance of the product The docu...

Страница 10: ... symbol is shown consult the corresponding section in the operating instructions 2 5 Tampering with the unit 11242 WARNING Tampering with the units can affect the safety of operators and machinery Tampering with the units is not allowed In case of non compliance our liability and warranty expire Do not open the devices Do not insert any objects into the devices Prevent metal foreign bodies from pe...

Страница 11: ...7 05 31 Functions and features 3 Functions and features Permitted use 11 Prohibited use 11 18761 3 1 Permitted use 22052 The device has been designed for use without a control cabinet in plant construction 3 2 Prohibited use 22053 The device may not be used beyond the limits of the technical data Technical data p 62 ...

Страница 12: ...ng Instructions IO Link Master with EtherNet IP interface StandardLine 8 Ports IP 65 IP 67 AL1122 2017 05 31 Function 4 Function Communication parameter setting evaluation 13 Digital inputs 15 IO Link supply 15 7482 ...

Страница 13: ...ions IO Link Master with EtherNet IP interface StandardLine 8 Ports IP 65 IP 67 AL1122 2017 05 31 Function 4 1 Communication parameter setting evaluation IO Link 14 EtherNet IP 14 Parameter setting 14 Visual indication 14 7485 ...

Страница 14: ... data between the connected IO Link devices and the higher level EtherNet IP controller 4 1 3 Parameter setting 7771 The device provides the following configuration options Parameter setting of the IO Link master of the AL1122 with parameter setting software LR DEVICE and or EtherNet IP projection software Parameter setting of the connected IO Link devices sensors actuators with parameter setting ...

Страница 15: ...s are on pin 2 of the IO Link ports X01 X08 All inputs refer to the potential of the device supply pin 3 4 3 IO Link supply 7623 The device has 8 supplies for IO Link devices sensors actuators The IO Link ports X01 X08 are ports class A Every supply provides short circuit monitoring The device ensures fire protection for the connected IO Link devices by providing a power restricted circuit at the ...

Страница 16: ...ice 16 22016 5 1 Mount the device 15540 Disconnect the system from power before installation For installation choose a flat mounting surface Please observe the maximum tightening torque Fix the unit to the mounting surface using 2 M5 mounting screws and washers Tightening torque 1 8 Nm Ground the unit via the two mounting screws of the upper mounting lugs ...

Страница 17: ...only suitable for operation on SELV PELV voltages Observe the information concerning IO Link circuits IO Link circuits p 20 The device contains components that can be damaged or destroyed by electrostatic discharge ESD Observe the required safety measures against electrostatic discharge The IP rating depends on the individual protection ratings of the unit the applied connection elements and the c...

Страница 18: ...ork e g EtherNet IP PLC additional EtherNet IP device Tightening torque 0 6 0 8 Nm Connect the unit via the M12 socket X21 and or X22 to the industrial Ethernet network e g laptop PC with installed parameter setting software LR DEVICE laptop PC with installed monitoring software LR SmartObserver Tightening torque 0 6 0 8 Nm For the connection use M12 connectors with protection rating IP 65 IP 67 o...

Страница 19: ...tors with protection rating IP 65 IP 67 or higher e g EVC493 Ports X01 X08 For use as IO Link port class B Connect the connector of the IO Link devices via the adapter with the M12 sockets X01 X08 Tightening torque 0 6 0 8 Nm To connect the devices use M12 connectors with protection rating IP 65 IP 67 or higher e g EVC693 Cover the unused sockets with M12 protective caps art no E73004 Tightening t...

Страница 20: ...nk ports p 19 The external supply for port class B operation must be galvanically separeted from the circuit of the AL1122 by assuring basic isolation according to EN61010 1 secondary circuit with maximum 30 V DC derived from applied voltage up to 300 V of overvoltage category II The isolation must be done both for IO Link devices and for the connection technology NOTICE Risk of material damage If...

Страница 21: ...0 V SELV PELV according to EN61010 1 secondary circuit with maximum 30 V DC derived from applied voltage up to 300 V of overvoltage category II Tightening torque 0 6 0 8 Nm Maximum cable length 25 m To connect the debice use M12 connectors with protection rating IP 65 IP 67 or higher e g EVC708 If the port X01 X08 will be used as IO Link ports Class B Connect adapter for Port Class B operation to ...

Страница 22: ...rating Instructions IO Link Master with EtherNet IP interface StandardLine 8 Ports IP 65 IP 67 AL1122 2017 05 31 Operating and display elements 7 Operating and display elements Overview 23 LED indicators 24 5440 ...

Страница 23: ...erating and display elements 7 1 Overview 22025 Status LEDs RDY NET and MOD Status LEDs p 24 Status LEDs LNK and ACT of the EtherNet IP ports 1 X21 and 2 X22 Ethernet interface p 24 Status LED US of the power supply X31 Voltage supply p 25 Status LEDs IOL and DI of the IO Link ports Class A X01 X08 IO Link ports Class A p 25 ...

Страница 24: ...properly flashes 1 Hz Error flashes 5 Hz Firmware update off Gateway does not function Device reboots NET green on Connection with the EtherNet IP PLC off No IP address red on IP address is used twice flashes No connection with the EtherNet IP PLC MOD green on No error off Voltage too low red on Module failed flashes Configuration of the module has been changed 7 2 2 Ethernet interface 22027 Each ...

Страница 25: ...plied or the applied supply voltage is too low 7 2 4 IO Link ports Class A 22029 Each IO Link port Class A X01 X08 has 2 LEDs marked as IOL and DI The LEDs indicate the status of the IO Link port Status LED Description IOL yellow on Interface configured as DI DO Pin 4 C Q ON off Interface configured as DI DO Pin 4 C Q OFF green on IO Link transmission functions properly flashes 1 Hz Interface conf...

Страница 26: ...ndardLine 8 Ports IP 65 IP 67 AL1122 2017 05 31 Configuration 8 Configuration Remarks 27 LR DEVICE Configure the device 32 LR DEVICE Configure IO Link devices 40 EtherNet IP Configure the device 42 EtherNet IP Configure IO Link devices 47 EtherNet IP Programmers notes 47 22367 ...

Страница 27: ...O Link Master with EtherNet IP interface StandardLine 8 Ports IP 65 IP 67 AL1122 2017 05 31 Configuration 8 1 Remarks Supported configuration options 28 Connection possibilities 28 Offline parameter setting 31 VPN connection 31 22369 ...

Страница 28: ...eously connected with the EtherNet IP control level PLC and the IT infrastructure level monitoring parameter setting The following connection possibilities exist Operation without EtherNet IP connection 4364 Operation as independent IO Link master with connected IO Link devices As an option several IO Link masters can be coupled via the EtherNet IP interfaces If necessary the IO Link masters can b...

Страница 29: ...master as EtherNet IP IO device As an option several IO Link masters can be coupled via the Ethernet interfaces X21 and X22 The complete monitoring of the process data and processing of alarms takes place via EtherNet IP mechanisms Parameter setting IO Link master EtherNet IP projection software IO Link device EtherNet IP projection software acyclic services Monitoring EtherNet IP projection softw...

Страница 30: ...e AL1122 can be connected via the two Ethernet interfaces X21 and X22 simultaneously with the EtherNet IP control level PLC and the IT infrastructure level monitoring parameter setting Parameter setting IO Link master LR DEVICE and or EtherNet IP projection software IO Link device LR DEVICE and or EtherNet IP projection software Monitoring LR SmartObserver and or EtherNet IP projection software To...

Страница 31: ...devices without being connected to the AL1122 The configuration created in this way can be stored as a file lrp and loaded to the device and activated at a later date Further information about offline parameter setting Operating instructions of the parameter setting software LR DEVICE 8 1 4 VPN connection 22762 An active VPN connection blocks the access of the parameter setting software LR DEVICE ...

Страница 32: ...quirements The device is properly connected with the LR DEVICE laptop PC via the EtherNet IP interface LR DEVICE is correctly installed Software manual LR DEVICE 1 Start LR DEVICE Start LR DEVICE Web browser shows LR DEVICE user interface 2 Scan network Scan network for new IO Link masters Under ONLINE the article number and the IP address of the device appear 3 Set network parameters Under ONLINE...

Страница 33: ...work menu The page shows the current settings Set the following parameters as required Name Description Possible values IP address IP address of the device e g 172 18 65 50 Subnet mask Subnet mask of the IP network e g 255 255 255 0 IP gateway address IP address of the gateway e g 172 18 65 1 Host name Name of the device in the EtherNet IP network e g al1xxx MAC address MAC address of the device T...

Страница 34: ...corder ro EtherNet IP has read and write access rights to parameters and process data EtherNet IP has read access rights to events alarms LR DEVICE only has read access rights to parameters process data and events alarms LineRecorder only LR DEVICE has read and write access rights to parameters to parameters and process data LR DEVICE has read access rights to events alarms EtherNet IP has no acce...

Страница 35: ...alue 35100 Source ID SmartObserver Source identifier with which the process data of the device is indicated in the SmartObserver String32 Port x LR events Operating mode of the IO Link port x 1 8 Disabled Cyclic transfer of the process data Enabled Event based transfer of the process data Port x LR cycle time ms Cycle time of the IO Link interface for cyclic transmission of the process data betwee...

Страница 36: ...set the operating mode of each IO Link port separately at any time Select Port x menu The page shows the current settings Set the following parameters as required Name Description Possible values Port x mode Operating mode of the IO Link port x 1 8 IO Link Operation as IO Link interface DI Operation as digital input DO Operation as digital output Disabled Interface deactivated Port x IO Link Cycle...

Страница 37: ...or ID and device ID No data storage Type compatible V1 0 device IO Link device is compatible with the V1 0 IO Link standard Verification whether it is an IO Link device of the same type validation via vendor ID and device ID No data storage Type compatible V1 1 device IO Link device is compatible with the V1 1 IO Link standard Verification whether it is an IO Link device of the same type validatio...

Страница 38: ...ndor ID and device ID The IO Link master saves the parameter values of the connected IO Link device once When connecting an IO Link device with factory settings the parameter values stored in the IO Link master are restored automatically on the IO Link device Port x IO Link Vendor ID ID of the manufacturer that is to be validated 0 65535 ID of the manufacturer of the IO Link device ifm electronic ...

Страница 39: ...onfiguration 8 2 6 Reset IO Link master to factory settings 12740 When resetting the AL1122 all parameters are reset to the Factory Settings p 60 To reset the device to factory settings Select Setup menu The page shows the current settings Click on Factory Reset to reset the AL1122 LR DEVICE sets the AL1122 factory settings ...

Страница 40: ...with one of the following values EtherNet IP LineRecorder LineRecorder only 1 Select IO Link master Start LR DEVICE Update IODD file library OR Import IODD file of the IO Link device manually Scan network for devices LR DEVICE recognises all IO Link masters of the EtherNet IP network 2 Add IO Link device Under ONLINE Click on the required AL1122 LR DEVICE automatically detects the IO Link devices ...

Страница 41: ...uration LR DEVICE shows AL1122 in OFFLINE section 2 Add IO Link device to configuration Under OFFLINE Click on AL1122 LR DEVICE shows the available parameters of the AL1122 Click on the symbol at the required port The dialogue window Gerät auswählen appears Select the required IO link device from the list Click on OK to add the selected IO Link device to the device configuration IO Link device app...

Страница 42: ...figure the device Registration of the EDS file 43 Integrate the AL1122 into the EtherNet IP network 43 Configure AL1122 44 Configure IO Link ports 45 1987 On the field bus side the device can be configured with any EtherNet IP compatible projection software The information in the following sections refers to the EtherNet IP projection software RSLogix 5000 ...

Страница 43: ...e AL1122 into the EtherNet IP network 8015 The device is integrated as module of an I O scanner in the EtherNet IP network Requirements The EDS file of the AL1122 is installed Registration of the EDS file p 43 1 Create open EtherNet IP project Start RSLogix 5000 Create new EtherNet IP project OR Open an existing EtherNet IP project 2 Configure EtherNet IP PLC and IO scanner Select and configure Et...

Страница 44: ... Link devices 0x00 Feldsbus LineRecorder EtherNet IP and LR DEVICE have read and write access rights to parameters and process data EtherNet IP and LR DEVICE have read access rights to events alarms 0x01 EtherNet IP LineRecorder ro EtherNet IP has read and write access rights to parameters and process data EtherNet IP has read access rights to events alarms LR DEVICE only has read access rights to...

Страница 45: ...nput DI 0x02 Operation as digital output DO 0x03 Operation as IO Link interface AL1122 C Port_Cycle_Time_Port_x Cycle time of the data transmission between the IO Link master and the IO Link device 0x00 The device automatically sets the fastest possible cycle time 0x01 2 milliseconds 0x02 4 milliseconds 0x03 8 milliseconds 0x04 16 milliseconds 0x05 32 milliseconds 0x06 64 milliseconds 0x07 128 mil...

Страница 46: ...O Link port 0x000000 0xFFFFFF AL1122 C Fail_Safe_Mode_Port_x Fail safe mode for output data when the EtherNet IP connection is interrupted 0x00 No Failsafe 0x01 Failsafe Reset Value 0x02 Failsafe Old Value 0x03 Failsafe with Pattern AL1122 C Fail_Safe_Value_DO_Port_x Fail safe value for the operating mode digital output DO 0x00 Failsafe Reset Value 0x01 Failsafe Old Value 0x02 Failsafe Set Value x...

Страница 47: ...tion for the execution of acyclic commands Execute acyclic commands p 49 Available parameters of the IO Link devices Operating instructions of the IO Link device 8 6 EtherNet IP Programmers notes 23323 The programmer can access the following data from the PLC application Read cyclic input and output data of the IO Link devices Read diagnostic and status information Change parameters of the IO Link...

Страница 48: ...e cyclic output data of the connected actuators and IO Link devices via the controller tags of the AL1122 To access the cyclic output data Starting RSLogix5000 Open a EtherNet IP project In the project tree Mouse click on Controller Tags AL1122 O The window shows the data structure with cyclic input data AL1122 O Data Mapping of the outputs on the data structure AL1122 C O Output assembly p 76 ...

Страница 49: ...Link master is transmitted in the Input Assembly The following table shows the general process of an acyclic communication via the acyclic command channel Step Output assembly Input assembly 1 Trigger 0 The data in the request area is invalid 2 Write the data of the request area Port bytes 4 and 5 Index bytes 6 and 7 Sub index bytes 8 and 9 Command byte 10 Data 11 43 3 Trigger 1 Command is transmi...

Страница 50: ... master when connecting a new IO Link device to the IO Link port Command 0x20 set validation ID data storage p 84 Set fail safe data pattern Behaviour of the outputs when the EtherNet IP connection is interrupted and setting of the corresponding fail safe values Command 0x30 set fail safe data pattern p 86 The port commands use the same mechanisms as the acyclic command channel Acyclic command cha...

Страница 51: ...tion of the voltage supply of the device 43 Status information IO Link port X01 58 Status information IO Link port X02 73 Status information IO Link port X03 88 Status information IO Link port X04 103 Status information IO Link port X05 118 Status information IO Link port X06 133 Status information IO Link port X07 148 Status information IO Link port X08 To access the cyclically transmitted diagno...

Страница 52: ...aster with EtherNet IP interface StandardLine 8 Ports IP 65 IP 67 AL1122 2017 05 31 Operation 9 Operation Read device information 53 Reboot the device 56 Error detection and elimination 56 Firmware update 57 Exchange IO Link device 58 22368 ...

Страница 53: ...ation 9 1 Read device information 12741 In order to get information about the current status of the hardware and software components of the device the user can use the following possibilities Web interface Read device and diagnostic information p 54 LR DEVICE Read device information p 55 EtherNet IP Read device information p 55 ...

Страница 54: ... Link interface MasterCycleTime Cycle time Vendor ID ID of the manufacturer of the IO Link device Device ID ID of the IO Link device Name Article number of the IO Link device For ifm articles This article number is stored along with a link to the produkt page on the ifm website Serial Serial number of the IO Link device LR Interval Cycle time for the communication with the SmartObserver Version in...

Страница 55: ... device AL1122 Manufacturer Manufacturer of the device ifm electronic gmbh Device ID IO Link ID of the device Serial number Serial number of the device Revision Hardware revision software revision of the unit Type of unit Name of the device IO Link master StandardLine EtherNet IP 8 ports IP 65 IP 67 Device status Current status of the slave no information about the condition OK no errors no warnin...

Страница 56: ...Scan the network for devices LR DEVICE recognises the AL1122 Under ONLINE Click on AL1122 Select the Setup section LR DEVICE shows available parameters Click on Restart to restart the device LR DEVICE restarts the AL1122 9 3 Error detection and elimination 20926 In order to recognise and eliminate errors the user can use the following resource Status LED of the unit LED indicators p 24 Cyclic diag...

Страница 57: ...ion on the device Requirements File with new firmware has been downloaded Ethernet connection between laptop PC and device is established 1 Call up web interface Start web browser Enter the following into the address field of the browser and confirm with ENTER IP Adresse des Geräts update Web browser shows the Firmware Update page 2 Load new firmware to AL1122 Click on Datei auswählen Dialogue win...

Страница 58: ...ink standard 1 1 or higher 1 Set data storage Set the following parameters of the IO Link port Validation Data Storage Type compatible V1 1 device with Restore OR Port x IO Link Validation Data Storage Type compatible V1 1 device with Restore Save changes 2 Exchange IO Link device Disconnect old IO Link device from AL1122 Connect new IO Link device with the same IO Link port of the AL1122 IO Link ...

Страница 59: ...L1122 2017 05 31 Maintenance 10 Maintenance 21577 The operation of the unit is maintenance free Clean the surface of the unit when necessary Do not use any caustic cleaning agents for this After use dispose of the unit in an environmentally friendly way in accordance with the applicable national regulations ...

Страница 60: ...IP 65 IP 67 AL1122 2017 05 31 Factory Settings 11 Factory Settings 23489 In the factory settings the device has the following parameter settings Parameter Factory setting IP address 192 168 1 250 Subnet mask 255 255 255 0 IP gateway address 0 0 0 0 Host name blank Data memory Data Storage blank ...

Страница 61: ...61 ifm Operating Instructions IO Link Master with EtherNet IP interface StandardLine 8 Ports IP 65 IP 67 AL1122 2017 05 31 Appendix 12 Appendix Technical data 62 EtherNet IP 66 7156 ...

Страница 62: ...terface StandardLine 8 Ports IP 65 IP 67 AL1122 2017 05 31 Appendix 12 1 Technical data Application 63 Electrical data 63 Inputs outputs 63 Inputs 63 Outputs 63 Interfaces 64 Operating conditions 64 Approvals tests 64 Mechanical data 65 Electrical connection 65 9011 ...

Страница 63: ...V PELV Current Consumption mA 300 3900 US Protection class III Sensor supply US Max current load total A 3 6 12 1 3 Inputs outputs 23711 Inputs outputs Total number of inputs and outputs 16 configurable 12 1 4 Inputs 22820 Inputs Number of digital inputs 16 IO Link Port Class A 8 x 2 Switching level high V 11 30 DC Switching level low V 0 5 DC Digital inputs protected against short circuits yes 12...

Страница 64: ...O Factory settings IP address 192 168 1 250 Subnet mask 255 255 255 0 Gateway IP address 0 0 0 0 MAC address see type label IO Link Master Transmission type COM 1 COM 2 COM 3 IO Link revision V1 1 Number of ports class A 8 12 1 7 Operating conditions 22823 Operating conditions Applications Indoor use Ambient temperature C 25 60 Storage temperature C 25 85 Max perm relative air humidity 90 Max heig...

Страница 65: ...nical data Weight g 350 Materials Housing PA socket brass nickel plated 12 1 10 Electrical connection 22826 Voltage supply IN X31 Connector M12 Wiring 1 24 V DC US 2 3 GND US 4 Ethernet IN OUT X21 X22 Connector M12 Wiring 1 TX 2 RX 3 TX 4 RX 5 Process connection IO Link Ports Class A X01 X0 IOL_AnzPorts Connector M12 Wiring 1 24 V DC US 2 DI 3 GND US 4 C Q IO Link 5 ...

Страница 66: ...6 ifm Operating Instructions IO Link Master with EtherNet IP interface StandardLine 8 Ports IP 65 IP 67 AL1122 2017 05 31 Appendix 12 2 EtherNet IP Parameter data 67 Cyclic data 71 Acyclic data 77 22433 ...

Страница 67: ...67 ifm Operating Instructions IO Link Master with EtherNet IP interface StandardLine 8 Ports IP 65 IP 67 AL1122 2017 05 31 Appendix 12 2 1 Parameter data Configuration assembly 68 1568 ...

Страница 68: ...70 4 X01 Byte swap Port configuration p 70 5 X01 Data storage and validation Port configuration p 70 6 X01 Vendor ID LSB Port configuration p 70 7 X01 Vendor ID MSB Port configuration p 70 8 X01 Device ID LSB Port configuration p 70 9 X01 Device ID Port configuration p 70 10 X01 Device ID MSB Port configuration p 70 11 X01 reserved 12 X01 Fail Safe Mode Port configuration p 70 13 X01 Fail safe val...

Страница 69: ...P only 0x03 Continue in Use Case Process data length 22987 Name Description Possible values Process data length Length of the process input data and process output data 0x00 2 bytes input data 2 bytes output data Input assembly 206 bytes Output assembly 62 bytes 0x01 4 bytes input data 4 bytes output data Input assembly 222 bytes Output assembly 78 bytes 0x02 8 bytes input data 8 bytes output data...

Страница 70: ...pping for IO Link process data deactivated 0x01 Byte swapping for IO Link process data activated X0n Validation ID Supported IO Link standard and behaviour of the IO Link master when connecting new IO Link devices to the IO Link port 0x00 No validation 0x01 Type compatible V1 0 device 0x02 Type compatible V1 1 device 0x03 Type compatible V1 1 device with Backup Restore 0x04 Type compatibe V1 1 dev...

Страница 71: ...71 ifm Operating Instructions IO Link Master with EtherNet IP interface StandardLine 8 Ports IP 65 IP 67 AL1122 2017 05 31 Appendix 12 2 2 Cyclic data Input assembly 72 Output assembly 76 22429 ...

Страница 72: ... Diagnostic vendor ID device ID events Mapping IO Link port information p 74 118 135 Port X05 Diagnostic vendor ID device ID events Mapping IO Link port information p 74 136 153 Port X06 Diagnostic vendor ID device ID events Mapping IO Link port information p 74 154 171 Port X07 Diagnostic vendor ID device ID events Mapping IO Link port information p 74 172 189 Port X08 Diagnostic vendor ID device...

Страница 73: ...of the IO Link port 1 Bit 0x0 OFF 0x1 ON Mapping Status information 15474 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 X08 Short OL X07 Short OL X06 Short OL X05 Short OL X04 Short OL X03 Short OL X02 Short OL X01 Short OL reserved reserved reserved reserved reserved reserved Sensor PWR AUX PWR Legend Short OL Occurrence of a short circuit or of an overvoltage on the IO Link port 1 bit 0x0 with...

Страница 74: ...1 IO Link active Device Conn Connection of the device 1 bit 0x0 not available 0x1 available Invalid Data Bit Status of the process input data on the IO Link port 1 bit 0x0 data valid 0x1 data invalid Wrong VID DID Status of the vendor ID device ID 1 bit 0x0 VID DID are correct 0x1 wrong VID or DID Wrong Cycle Time Status of the cycle time 1 bit 0x0 cycle time is correct 0x1 wrong cycle time Wrong ...

Страница 75: ...IP 65 IP 67 AL1122 2017 05 31 Appendix Event Mode Event mode 2 bits depends on the device operating instructions of the IO Link device Event Type Event type 2 bits Event Source Evens source 1 bit Event Instance Event instance 3 bits Event Code 1 Event code 8 bits Event Code 2 Event code 8 bits ...

Страница 76: ...yclic output data n bytes 46 2n Port X03 Acyclic output data n bytes 46 3n Port X04 Acyclic output data n bytes 46 4n Port X05 Acyclic output data n bytes 46 5n Port X06 Acyclic output data n bytes 46 6n Port X07 Acyclic output data n bytes 46 7n Port X08 Acyclic output data n bytes Legend n 2 4 8 16 32 is determined by the parameter Prozess_Data_Length Process data length p 69 Mapping Digital out...

Страница 77: ...nnel 10236 In the cyclic process data command channels for the transmission of acyclic data is available Object Contents Bytes Access Output assembly Request channel field bus PLC IO Link master Request channel p 78 4 45 r w Input assembly Response channel IO Link master fieldbus PLC Response channel p 79 4 45 r Legend r r w only read access rights read and write access rights ...

Страница 78: ...k port high byte Port no 0xXXYY Port no MSB 0xXX 8 bits 0x00 Index LSB Index of the IO Link object low byte Index 0xXXYY Index LSB 0xYY 8 bits 0x00 0xFF Index MSB Index of the IO Link object high byte Index 0xXXYY Index MSB 0xXX 8 bits 0x00 0xFF Sub index LSB Sub index of the IO Link object low byte Sub index 0xXXYY Sub index LSB 0xYY 8 bits 0x00 0xFF Sub index MSB Sub index of the IO Link object ...

Страница 79: ...ort no 0xXXYY Port no MSB 0xXX 8 bits 0x00 Index LSB Index of the IO Link object low byte Index 0xXXYY Index LSB 0xYY 8 bits 0x00 0xFF Index MSB Index of the IO Link object high byte Index 0xXXYY Index MSB 0xXX 8 bits 0x00 0xFF Sub index LSB Sub index of the IO Link object low byte Sub index 0xXXYY Sub index LSB 0xYY 8 bits 0x00 0xFF Sub index MSB Sub index of the IO Link object high byte Sub inde...

Страница 80: ... byte n 8 bits 0x00 0xFF Failure codes 15475 Error code Description 0x71 Service not available unknown command has been sent to the IO Link port 0x72 Port blocked another cyclic process accesses the IO Link port 0x74 Invalid data wrong parameter has been sent in the command 0x76 Wrong port wrong port number 0x77 Wrong port function wrong port function or wrong parameter has been sent to the device...

Страница 81: ...ink Master with EtherNet IP interface StandardLine 8 Ports IP 65 IP 67 AL1122 2017 05 31 Appendix Acyclic commands Command 0x10 set mode 82 Command 0x20 set validation ID data storage 84 Command 0x30 set fail safe data pattern 86 22631 ...

Страница 82: ...B 6 reserved 7 reserved 8 reserved 9 reserved 10 Trigger 0x10 11 Target mode 12 45 reserved Legend Port no LSB Number of the IO Link port low byte Port no 0xXXYY Port no LSB 0xYY 8 bits 0x01 port X01 0x02 port X02 0x08 port X08 Port no MSB Number of the IO Link port high byte Port no 0xXXYY Port no MSB 0xXX 8 bits 0x00 Trigger Control of the command execution 1 bit 0x0 do not process command 0x1 e...

Страница 83: ...the IO Link port low byte Port no 0xXXYY Port no LSB 0xYY 8 bits 0x01 port X01 0x02 port X02 0x08 Port X08 Port no MSB Number of the IO Link port high byte Port no 0xXXYY Port no MSB 0xXX 8 bits 0x00 Handshake Status of the execution of the command 1 bit 0x0 command is executed 0x1 execution of the command was successful Result Error indication 8 bits 0x00 no errors 0x01 errors occurred Target mod...

Страница 84: ...7 reserved 8 reserved 9 reserved 10 Trigger 0x20 11 Validation ID 9 42 reserved Legend Port no LSB Number of the IO Link port low byte Port no 0xXXYY Port no LSB 0xYY 8 bit 0x01 port X01 0x02 port X02 0x08 port X08 Port no MSB Number of the IO Link port high byte Port no 0xXXYY Port no MSB 0xXX 8 bits 0x00 Trigger Control command execution 1 bit 0x0 do not process command 0x1 execute command Valid...

Страница 85: ...0xYY 8 bits 0x01 port X01 0x02 port X02 0x08 port X08 Port no MSB Number of the IO Link port high byte Port no 0xXXYY Port no MSB 0xXX 8 bits 0x00 Handshake Status of the execution of the command 1 bit 0x0 command is executed 0x1 execution of the command was successful Result Error indication 8 bits 0x00 no errors 0x01 errors occurred Validation ID Behaviour of the IO Link master when connecting a...

Страница 86: ...10 Trigger 0x30 11 Fail safe mode 12 Byte Length N 13 Fail safe data byte 0 44 Fail safe data byte 31 45 reserved Legend Port no LSB Number of the IO Link port low byte Port no 0xXXYY Port no LSB 0xYY 8 bits 0x01 port X01 0x02 port X02 0x08 port X08 Port no MSB Number of the IO Link port high byte Port no 0xXXYY Port no MSB 0xXX 8 bits 0x00 Fail safe mode Behaviour of the outputs when the EtherNet...

Страница 87: ...O Link port low byte Port no 0xXXYY Port no LSB 0xYY 8 bits 0x01 port X01 0x02 port X02 0x08 port X08 Port no MSB Number of the IO Link port high byte Port no 0xXXYY Port no MSB 0xXX 8 bits 0x00 Handshake Status of the execution of the command 1 bit 0x0 command is executed 0x1 execution of the command was successful Result Error indication 8 bits 0x00 no errors 0x01 errors occurred Fail safe mode ...

Страница 88: ... classes 89 Identity Object object class 0x01 90 Message Router Object object class 0x02 92 Assembly Object object class 0x04 93 Connection Manager Object object class 0x06 94 Device Level Ring Object object class 0x47 95 Quality of Service object class 0x48 96 IO Link requests object class 0x80 97 TCP IP object object class 0xF5 104 Ethernet Link Object object class 0xF6 106 22640 ...

Страница 89: ...6 4C Write ISDU Write ISDU 78 4E Forward Close Close connection 84 54 Forward Open Open new connection CIP object classes 23652 The device supports the following CIP object classes Class code Object type Reference dec hex 01 01 Identity Object Identity Object object class 0x01 p 90 02 02 Message Router Object Message Router Object object class 0x02 p 92 04 04 Assembly Object Assembly Object object...

Страница 90: ...2 Get Device type UINT Type of unit 12 3 Get Product code UINT Identification of a particular product of a vendor AL1122 4 Get Revision STRUCT Revision of the article that is represented by the Identity Object 1 1 Major revision USINT Main revision 1 127 1 Minor revision USINT Side revision 3 digits if necessary with zeros in the beginning 1 5 Get Status WORD Status of the device 6 Get Serial numb...

Страница 91: ...Reset yes yes Reset 14 0E Get_Attribute_Single yes yes Read single attribute 16 10 Set_Attribute_Single yes yes Change single attribute If an Identity Object receives a reset request it carries out the following actions It checks if it supports the requested reset type It responds to the request It tries to execute the requested reset type Supported reset types 0 Reboot the device obligatory for a...

Страница 92: ...cess Name Data type Description Value 1 Get Revision UINT Revision of the object 1 2 Get Max instance UINT Max number of instances of the object 1 3 Get Number of Instances UINT Number of instances 1 6 Get Maximum ID Number Class Attributes UINT ID of the last class attribute 7 7 Get Maximum ID Number Instance Attributes UINT ID of the last instance attribute 0 Instance attributes 23696 The object...

Страница 93: ...r of Instances UINT Number of instances 3 6 Get Maximum ID Number Class Attributes UINT ID of the last class attribute 7 7 Get Maximum ID Number Instance Attributes UINT ID of the last instance attribute 4 Instance attributes 23692 Attr ID Access Name Data type Description Preset 100 Get Input assembly STRUCT Cyclic input data Input assembly p 72 150 Get Set Output assembly STRUCT Cyclic output da...

Страница 94: ...instance UINT Max number of instances of the object 1 3 Get Number of Instances UINT Number of instances 3 6 Get Maximum ID Number Class Attributes UINT ID of the last class attribute 7 7 Get Maximum ID Number Instance Attributes UINT ID of the last instance attribute 0 Instance attributes 23696 The object has no instance attributes Supported services 23701 Service code Name Class Attribute Descri...

Страница 95: ...ce attribute 12 Instance attributes 23659 Attr ID Access Name Data type Description Preset 1 Get Network Topology USINT current network topology 0 2 Get Network status USINT current network status 0 10 Get Active Supervisor STRUCT of Identification of the supervisor 0 UDINT IP address of the supervisor ARRAY of 6 USINT s MAC address of the supervisor 12 Get Capability Flags DWORD DLR functions of ...

Страница 96: ...ibute 8 Instance attributes 23663 Attr ID Access Name Data type Description Value 1 Get 802 1Q tagRevision USINT Current network topology 0 2 Get Set DSCP PTP Event USINT DSCP value for PTP event frames 59 3 Get Set DSCP PTP general USINT DSCP value for PTP general frames 47 4 Get Set DSCP PTP Urgent USINT DSCP value for implicit messages with urgent priority 55 5 Get Set DSCP Scheduled USINT DSCP...

Страница 97: ...chanisms of the CIP addressing on the IO Link protocol Class attributes 23668 Attr ID Access Name Data type Description Value 1 Get Revision UINT Revision of the object 4 2 Get Max instance UINT Max number of instances of the object 2 6 Get Maximum ID Number Class Attributes UINT Number of instances of the object 8 Instance attributes 23669 The required IO Link port of the device is addressed via ...

Страница 98: ...e ID USINT 0x4B Read Request ISDU_Read User specific service data UINT Index IO Link ISDU object index USINT Subindex IO Link ISDU object sub index Read response 23114 Positive response If the service has been executed successfully Error Code 0 the read data are returned bit by bit User Specific Service Data The answer has the following format CIP format Data type MSG Config IO Link mapping Class ...

Страница 99: ... not available The IO Link port is busy processing another acyclic service 0x05 Invalid class ID or instance ID 0x08 Wrong service ID only service code 0x4B or 0x4C is permitted 0x09 Wrong attribute ID wrong port number 0x20 Invalid parameter value e g invalid length 0x1E Embedded service error Error occurred during an IO Link service Byte 0 and byte 1 of the User Specific Service Data contain the...

Страница 100: ...ion of the request the response area has the following content CIP format Data type MSG Config Description Class ID UINT 0x80 Object class IO Link Requests Instance ID UINT 0x01 IO Link master Attributes USINT 0x02 Port number Service code ID USINT 0x4B Service ISDU_Read Error code USINT 0x00 Request processed successfully Extended error code USINT 0x00 User specific service data USINT e g 0x12 Pa...

Страница 101: ...apping Class UINT 0x80 IO Link acyclic access Instance UINT 0x1 IO Link master Attribute USINT 0x01 0x08 Port number Service code ID USINT 0x4C Write Request ISDU_Write User specific service data UINT Index IO Link ISDU object index USINT Subindex IO Link ISDU object sub index USINT e g 0xAB IO Link ISDU data byte 0 USINT e g 0xBC IO Link ISDU data byte 1 Write response 23115 Positive response If ...

Страница 102: ...e not available The IO Link port is busy processing another acyclic service 0x05 Invalid class ID or instance ID 0x08 Wrong service ID only service code 0x4B or 0x4C is permitted 0x09 Wrong attribute ID wrong port number 0x20 Invalid parameter value e g invalid length 0x1E Embedded service error Error occurred during an IO Link service Byte 0 and byte 1 of the User Specific Service Data contain th...

Страница 103: ...SDU object sub index USINT 0xAB New parameter value MSB USINT 0xCD New parameter value LSB After successful execution of the request the response area has the following content CIP format Data type MSG Config Description Class ID UINT 0x80 Object class IO Link Requests Instance ID UINT 0x01 IO Link master Attributes USINT 0x03 Port number Service code ID USINT 0x4B Service ISDU_Write Error code US...

Страница 104: ...onfiguration status of the interface Bit 4 Mcast pending always 0 Bit 5 Interface configuration pending Bit 6 ACD Status Bit 7 ACD Fault Bit 8 31 reserved 2 Get Configuration Capability DWORD Functions of the interface flags 0x95 BOOTP DHCP Client TCP IP configurable ACD capable Bit 0 BOOTP Client Bit 1 reserved Bit 2 DHCP Client Bit 3 reserved Bit 4 TCP IP configurable via EtherNet IP Bit 5 reser...

Страница 105: ...ING Host name 0 0 no name configured 8 Get TTL value TTL value 1 9 Get Mcast Config 0 10 Get Set SelectAcd BOOL activate ACD 1 0 deactivate 1 activate 11 Get Set Last Conflict Detected STRUCT Structure with information via the latest detected conflict 0 USINT Condition of the ACD activity with the latest detected conflict 0 Noconflictdetetcted 1 Probelpv4Address 2 OngoingDetection 3 SemiActiveProb...

Страница 106: ...e in bytes s 10 Mbps 100 Mbps 100 2 Get Interface Status Flags DWORD Status flag of the interface 0x20 Bit 0 Link status Bit 1 Half full duplex Bit 2 4 Auto negotiation status Bit 5 Manual setting requires reset Bit 6 Local Hardware Fault Bit 7 31 reserved 3 Get Physical Address ARRAY of 6 USINTS MAC address 4 Get Interface Counters STRUCT of 11 UDINTs Interface specific counter 5 Get Media counte...

Страница 107: ...1 0 reserved 1 Activate interface 2 Deactivate interface 3 255 reserved 10 Get Interface label SHORT_ STRING Designation of the interface X21 instance 1 X22 instance 2 11 Get Interface capability STRUCT of Capabilities of the interface DWORD Transmission rate 10 10 Mbps 100 100 Mbps DWORD Duplex mode HD Half duplex FD Full duplex 300 Get Set MDIX MDIX configuration 3 0 1 MDI 2 MDIX 3 autoMDI 4 255...

Страница 108: ...108 ifm Operating Instructions IO Link Master with EtherNet IP interface StandardLine 8 Ports IP 65 IP 67 AL1122 2017 05 31 Appendix ...

Страница 109: ...rface 24 Ethernet Link Object object class 0xF6 106 Ethernet ports 18 EtherNet IP 14 66 Configure IO Link devices 47 Configure the device 42 Programmers notes 47 Read device information 55 EtherNet IP mechanisms for acyclic commands 50 Example changing the parameter value of an IO Link device 103 reading the parameter value of anIO Link device 100 Exchange IO Link device 58 Execute acyclic command...

Страница 110: ...48 96 R Read cyclic input data 47 Read device information 53 Read diagnostic and status information 51 Read Request 98 Read response 98 Read_ISDU 98 Reboot the device 56 Registration of the EDS file 43 Remarks 27 Request channel 78 Required background knowledge 9 Reset IO Link master to factory settings 39 Response channel 79 S Safety instructions 8 Safety symbols on the device 10 Set device valid...

Страница 111: ...ampton Middlesex TW12 2HD Tel 44 208 213 0000 ifm electronic Monoprosopi E P E 15125 Amaroussio Tel 30 210 6180090 ifm electronic kft 9028 Györ Tel 36 96 518 397 ifm electronic s a 20041 Agrate Brianza MI Tel 39 039 68 99 982 Astragal Ltd Azur 58001 Tel 972 3 559 1660 ifm electronic India Branch Office Kolhapur 416234 Tel 91 231 267 27 70 efector co ltd Chiba shi Chiba 261 7118 Tel 81 043 299 2070...

Отзывы: