Operating instructions 

ATEX ClassicLine module 

AC535A

7390947/00     08/2012

UK

Содержание A5 interface AC535A

Страница 1: ...Operating instructions ATEX ClassicLine module AC535A 7390947 00 08 2012 UK ...

Страница 2: ...instructions 3 2 Functions and features 3 3 Operating and display elements 4 4 Installation 5 5 Addressing 10 5 1 Addressing with the AC1154 addressing unit 10 6 Electrical connection 11 7 Operation 11 8 Technical data 11 ...

Страница 3: ...fety instructions Please read the product description prior to installing the unit Ensure that the product is suitable for your application without any restrictions The unit conforms to the relevant regulations and EU directives Improper use or non intended use may lead to malfunctions of the unit or to unwanted effects in your application That is why installation electrical connection set up oper...

Страница 4: ...4 3 Operating and display elements 1 8 7 6 5 4 3 2 1 addressing interface 2 LED PWR 3 LED FAULT 4 LED 1 5 labels 6 8 M12 sockets 7 LED 2 8 LED AUX Scale drawing ...

Страница 5: ...5 UK 4 Installation 1 Alignment of the flat cable on delivery Carefully place the yellow and black AS i flat cable into the profile slot 2 Mount the upper part 3 Lock the unit ...

Страница 6: ...6 With the supplied lower part the flat cable can be aligned in three direc tions For the requested direction place the flat cable guide 1 accordingly ...

Страница 7: ...7 UK A Settings at the lower part Select the position 1 2 or 3 depending on the requested flat cable alignment A factory setting B C ...

Страница 8: ...upper part Then set the selected position at the upper part To do so turn the triangle to the corresponding number fig D1 and D2 D1 Use a tool e g a screwdriver figure D1 or the yellow black flat cable guide figure D2 D2 ...

Страница 9: ...9 UK Open the unit Open the unit using a tool as shown e g screwdriver Take care in laying the AS i flat cable the flat cable should be laid straight for about 15 cm ...

Страница 10: ...rameter P3 must be 1 and the output bit D3 must be 0 The output bit D3 and the parameter bit P3 must not be used default setting If a slave with the extended addressing mode is used in combination with a master of the first generation version 2 0 an address between 1A and 31A must be assigned to this slave AC535A 4 inputs 4 outputs AS i profile S 7 A 7 extended addressing mode yes AUX Data bit D0 ...

Страница 11: ... so that the locking mechanism is not affected LED PWR green AS i voltage supply ok LED FAULT red lights AS i communication error slave does not par ticipate in the normal exchange of data e g slave address 0 LED FAULT red flashes peripheral fault e g sensor supply output overloaded or shorted LED 1 yellow input output switched LED 2 yellow logic state of the outputs LED AUX green AUX voltage supp...