Page
26
REQUEST AMPLIFIER STATUS
(POWER AND METERING)
CODE
Amplifier FUNCTION
POWERFWD
Returns Forward Power Value in Watts,
‘POWER FWD: XXXXX W’
POWERRFL
Returns Reflected Power Value in Watts,
‘POWER RFL: XXXXX W’
PS1V
Returns Power Supply 1 Volts Value in Volts,
‘PWRSPLYV1: XXXXX V’
PS1I
Returns Power Supply 1 Current Value in Amps,
‘PWRSPLYI1: XXXXX A’
PS2V
Returns Power Supply 2 Volts Value , [ If Applicable ]
PS2I
Returns Power Supply 2 Current Value [ If Applicable ]
PS3V
Returns Power Supply 3 Volts Value , [ If Applicable ]
PS3I
Returns Power Supply 3 Current Value [ If Applicable ]
PS4V
Returns Power Supply 4 Volts Value , [ If Applicable ]
PS4I
Returns Power Supply 4 Current Value [ If Applicable ]
TOTALH
Returns Total hours unit is on,
‘TOTAL HRS: XXXXX’
OPERATEH
Returns Operation Hours Value,
‘OPERATE HRS: XXXXX’
BAND1
Selects Band 1 of Operation [ In Dual Band units only ]
BAND2
Selects Band 2 of Operation [ In Dual Band units only ]
NOLEV
Selects NO Leveling [ Optional ]
INTLEV
Selects INTERNAL Leveling [ Optional ]
EXTLEV
Selects EXTERNAL Leveling [ Optional ]
QUIETOFF
Selects QUIETING to OFF [ Optional ]
QUIETAUTO
Selects QUIETING to AUTO mode [ Optional ]
QUIETSTATUS
Returns Quieting mode of operation [ Optional ]
‘QUIETING OFF’
‘QUIETING AUTO’
ZEROATT
Sets the Amplifier for ZERO Attenuation & Returns,
‘GAIN: 00100 %’
FULLATT
Sets the Amplifier for FULL Attenuation & Returns,
‘GAIN: 00000 %’
GAIN
Returns Gain Value in percentage,
‘GAIN: XXXXX%’
MODEL
Returns Model number of the unit
SN
Returns Serial number of the unit
*IDN?
Returns ASCII response comprising of four data fields in the format
<Manufacturer>, <Model>, <Serial Number>, <Firmware Version>
*RST
Reset Command, Sets the Amplifier to the factory default power up state (reboots MPU)
NOTES:
1. ALL GPIB COMMANDS AND REQUESTS MUST CONSIST ENTIRELY OF UPPER CASE ALPHANUMERIC
CHARACTERS.
2. WHEN SENDING COMMAND STRINGS TO THE AMPLIFIER, A CARRIAGE RETURN CHARACTER
(0Dh)
FOLLOWED BY A LINE FEED CHARACTER
(0Ah)
, MUST ALWAYS BE APPENDED TO THE COMMAND, and
OTHERWISE THE AMPLIFIER WILL WAIT INDEFINITELY FOR THE
CR-LF
COMBINATION.
Содержание S251-2KWP