www.ies-synergy.com
User Manual
DUM3017446-EN
9
Internal DC output protection
Over temperature protection
-
70
°C
Reverse polarity protection
Yes
DC output Contactor
Yes (2 pôles)
Rated Current Fuse (output)
I
FUSE
125
A
Max time for DC line discharge < 60V
T
<60V
1
s
AC output
AC Output voltage
V
AC
_nom
400 V
AC
± 10%
AC Output current
I
AC
_max
32 A
Nom
Max Output Power
P
OUT
22 kVA
Max
Car Plug socket
Plug #3
AC type 2 S
Type of connection
Detachable cable
Internal AC output protection
Inrush current
230A during 100 µs
Short circuit Socket I²t
A²s
75 000
Circuit breaker for AC circuit
50A curve C
Embedded Insulation device of charger module
Response time (tan)
< 3sec. for asymmetrical fault
< 62sec. for symmetrical fault
Self test time
At power on and every 60s during charge
Measurement method
Continuous and switching measurement resistor method
Fault trigger threshold (CCS, CHAdeMO and
GB before the charge only)
100 Ω/V
± 10%
Warning detection threshold (CCS only)
500 Ω/V
± 10%
System leakage capacity Ce
≤ 1µF : response value (Ran) and time (tan) are not guar
-
anteed for capacity above 1µF
Radio Frequency characteristics
The equipment module is designed to provide customers with global network coverage on the connec-
tivity of UMTS/HSPA+, and it is also fully backward compatible with the existing EDGE and GSM/GPRS
networks.
Output power (dBm)
Class 4 (33dBm±2dB) for GSM850 and EGSM900
Class 1 (30dBm±2dB) for DCS1800 and PCS1900
Class E2 (27dBm±3dB) for GSM850 and EGSM900 8-PSK
Class E2 (26dBm+3/-4dB) for DCS1800 and PCS1900 8-PSK
Class 3 (24dBm+1/-3dB) for UMTS800/850/900/1900/2100
General & dimensions
External dimensions (without support) (mm)
H x W x D
1750 x 700 x 356 mm
External dimensions (with support) (mm)
H x W x D
1758 x 1000 x 396 mm
Weight (without cable and connector)
kg
200 kg
Max
Type of installation
Fastening to concrete slab with suitable fas-
tening points
Fixation points
4 goujons M14 (non fournis)
Mechanical impact resistance (not the screen)
IK
IK10
Protection type (EN60529)
IP
IP55