5. Specification
Main supply
Mains supply 3-phase L
1
/L
2
/L
3
+ N + PE
DC charger input
Mains 3-phase voltage range (phase to phase)
V
AC
400 V
AC
± 10%
Earthed electrical system
TT; TN
Frequency range
f
50 Hz
± 10%
Nominal input current
I
AC
38A
Nom
Maximum input current
I
AC
42A
Max
Power Factor
PF
0,99
Nom
Efficiency
ɳ
95 %
Max
Harmonic current @ nominal network voltage
THDi
< 13 %
Max
AC charger input
Mains 3-phase voltage range (phase to phase)
V
AC
400 V
AC
± 10%
Earthed electrical system
TT; TN
Frequency range
f
50 Hz
± 10%
Nominal input current
I
AC
32A
Nom
Maximum input current
I
AC
35A
Max
Technical specifications
DC charger internal AC input protection
Inrush current limitation per phase
I
APPEL LIMITE
< 3 x I
AC
Max
Rated Current Fuse (per module)
I
COUPURE
Nominal 80A
typ
Breaking capacity of fuses
I
COUPURE
Capacité 80 000A
Max
Max earth leakage current
I
FUITE
< 5 mA
Max
Overvoltage category (IEC60664-1)
III
Charger short-circuit current resistance
I
CC
6 kA
Max
Internal DC Output
COMBO 2 output voltage
V
DC
_max
530 V
DC
Max
V
DC
_min
200 V
DC
Min
CHAdeMO output voltage
V
DC
_max
500 V
DC
Max
V
DC
_min
150 V
DC
Min
Output current
I
DC
_max
65A
(1)(2)
Max
I
DC
_min
1,5A
Min
Max Output Power
P
OUT
24kW
Max
Output connector (charging station side)
Permanent mounting
Car Plug connector
Plug #1
COMBO 2
Plug #2
CHAdeMO
Output cable length
-
5
Meters
Internal DC output protection
Hardware and software short circuit protection
Oui
Software and Hardware over voltage protection
adjustable
+10% max