2.1.1.2. Connecting the Printer to the Data Communications
System
CAUTION
To comply with class A FCC regulations it is
necessary to use a data cable provided with a
braided shield.
Use a shielded RS232 cable fitted with metal plated
connector hoods. The cable shield must be linked to
these hoods and cable length must not exceed 15 m
(49.2 ft).
The length of a USB cable must not exceed 5 m (16.4
ft).
Depending on the printer configuration, connect either
the:
- serial data I/O cable (1) to the RS232 connector,
located at the rear of the printer, or the
- USB cable (2) to the corresponding connector at the
rear of the printer.
1 - Serial RS232 data I/O cable
2 - USB cable
Figure 2.2
Connecting the I/O Data cable
PRINTER IER 506B
User Guide
Page 12
N0B402A Rev. 1
May 25, 2007