background image

 

 

IOVU-570M Panel PC 

Page i 

IEI Technology Corp. 

User Manual 

 

MODEL: 

IOVU-570M 

Panel PC, 5.7" Touch Screen, 520 MHz Marvell XScale PXA270,

Fast Ethernet, 2 x USB, 802.11b/g Wireless, RS-232/422/485 

RoHS Compliant, IP 64 Protection 

Rev. 1.00 – 24 June, 2009 

Содержание IOVU-570M

Страница 1: ...Page i IEI Technology Corp User Manual MODEL IOVU 570M Panel PC 5 7 Touch Screen 520 MHz Marvell XScale PXA270 Fast Ethernet 2 x USB 802 11b g Wireless RS 232 422 485 RoHS Compliant IP 64 Protection Rev 1 00 24 June 2009 ...

Страница 2: ...IOVU 570M Panel PC Page ii Revision Date Version Changes 24 June 2009 1 00 Initial release ...

Страница 3: ... arising out of the use or inability to use the product or documentation even if advised of the possibility of such damages This document contains proprietary information protected by copyright All rights are reserved No part of this manual may be reproduced by any mechanical electronic or other means in any form without prior written permission of the manufacturer TRADEMARKS All registered tradem...

Страница 4: ... STATIC PRECAUTIONS 11 3 2 UNPACKING PRECAUTIONS 11 3 3 UNPACKING CHECKLIST 12 3 4 OPTIONAL ITEMS 13 4 INSTALLATION 15 4 1 INSTALLATION PRECAUTIONS 16 4 2 SD CARD INSTALLATION 16 4 3 EXTERNAL PERIPHERAL INTERFACE CONNECTORS 17 4 3 1 12 V 36 V DC Terminal Block 18 4 3 2 RS 232 422 485 Serial Port 18 4 3 2 1 Connecting the Serial Port 18 4 3 2 2 RS 232 422 485 Selection 19 4 3 2 3 Pinouts 20 4 3 2 4...

Страница 5: ...IP 64 COMPLIANT FRONT PANEL 33 B SAFETY PRECAUTIONS 34 B 1 SAFETY PRECAUTIONS 35 B 1 1 General Safety Precautions 35 B 1 2 Anti static Precautions 36 B 2 MAINTENANCE AND CLEANING PRECAUTIONS 36 B 2 1 Maintenance and Cleaning 36 B 2 2 Cleaning Tools 37 C HAZARDOUS MATERIALS DISCLOSURE 38 C 1 HAZARDOUS MATERIALS DISCLOSURE TABLE FOR IPB PRODUCTS CERTIFIED AS ROHS COMPLIANT UNDER 2002 95 EC WITHOUT M...

Страница 6: ...erminal Block 18 Figure 4 4 Serial Device Connector 19 Figure 4 5 Serial Port Mode Setting 20 Figure 4 6 Serial Port Pinouts 21 Figure 4 7 USB Connector 22 Figure 4 8 LAN Connection 23 Figure 4 9 Ethernet Connector 24 Figure 4 10 Wall mounting Bracket 25 Figure 4 11 Chassis Support Screws 26 Figure 4 12 Secure the IOVU 570M 27 Figure 4 13 IOVU 570M Panel Opening mm 28 Figure 4 14 Panel Mounting Cl...

Страница 7: ...ts 12 Table 3 2 Optional Items 14 Table 4 1 External Interface Connectors 17 Table 4 2 12 36 V Power Connector Pinouts 18 Table 4 3 Serial Port Pinouts 21 Table 4 4 Serial Port Terminator Settings 21 Table 4 5 USB Connector Pinouts 22 Table 4 6 Ethernet Connector Pinouts 24 Table 4 7 Ethernet Connector LEDs 24 ...

Страница 8: ......

Страница 9: ...IOVU 570M Panel PC Page 1 Chapter 1 1 Introduction ...

Страница 10: ... easily customize the operating system according to needs The IOVU 570M is an extremely low power Panel PC The system is fanless which allows quiet and reliable operation 1 2 Benefits Some of the IOVU 570M benefits include Customizable operating system to suit application needs Less downtime from overheating because there are not fans to fail Cost savings with low power consumption Easy installati...

Страница 11: ...nput RoHS compliant 1 4 Technical Specifications The IOVU 570M technical specifications are listed in Table 1 1 Specifications System CPU 520 MHz Marvell XScale PXA270 processor Memory 128 MB of SDRAM 1 0 GB SD card Real time Clock Battery backup RTC Watchdog Timer Software programmable supports 1 255 sec system reset Reset Reset button Display Display Type TFT LCD screen Display Size 5 7 Resoluti...

Страница 12: ...H non condensing Vibration Operating Random Vibration Mode MIL STD 810F 514 5C 3 1 Axes 3 axs Vertical Transverse Longitudinal 2 10 500 Hz 60min axis 3 Equivalent to Z 2 18 Grms X 1 6 Grms Y 1 96 Grms Front Panel Color Pantone Black C Physical Dimensions 180 mm x 135 8 mm x 46 7 mm Ingress Protection IP 64 compliant front panel Table 1 1 Technical Specifications 1 5 Certifications All IOVU 570M se...

Страница 13: ...IOVU 570M Panel PC Page 5 Chapter 2 2 Detailed Specifications ...

Страница 14: ...WVGA 16 bit color touch screen LCD in an ABS PC plastic frame Figure 2 1 Front Panel 2 2 Connector Panel All external peripheral interface connectors are located on the bottom panel of the IOVU 570M The peripheral interface connectors are shown in Figure 2 2 Figure 2 2 IOVU 570M Peripheral Connectors ...

Страница 15: ...IOVU 570M Panel PC Page 7 External peripheral interface connectors on the IOVU 570M include 1 x DC IN bare wire terminal block 2 x RJ 45 LAN connectors 1 x RS 232 422 485 connector 2 x USB connectors ...

Страница 16: ...M Panel PC Page 8 2 3 Dimensions The physical dimensions of the IOVU 570M are shown in Figure 2 3 and listed below Width 180 mm Height 135 8 mm Depth 46 7 mm Figure 2 3 IOVU 570M Physical Dimensions millimeters ...

Страница 17: ... you need to remove a part for maintenance or upgrading switch off the power supply and unplug the power cord first The IOVU 570M has a terminal block connector on the bottom panel The IOVU 570M also supports Power over Ethernet PoE through one of its LAN ports ...

Страница 18: ...IOVU 570M Panel PC Page 10 Chapter 3 3 Unpacking ...

Страница 19: ...ristband Wearing a simple anti static wristband can help to prevent ESD from damaging the board Self grounding Before handling the board touch any grounded conducting material During the time the board is handled frequently touch any conducting materials that are connected to the ground Use an anti static pad When configuring the IOVU 570M place it on an antic static pad This reduces the possibili...

Страница 20: ...vendor you purchased the IOVU 570M from or contact an IEI sales representative directly To contact an IEI sales representative please send an email to sales iei com tw The IOVU 570M is shipped with the following components Quantity Item and Part Number Image 1 IOVU 570M 1 Utility CD including SDK utilities and technical documentation 1 Null modem cable 1 Touch pen Table 3 1 Package List Contents ...

Страница 21: ...8 VESA 75 wall mount kit AFLWK 07 LCD monitor PPC arm kit load capacity of 3kg 7kg ARM 11 RS LCD monitor PPC stand kit for VESA 75 up to 5kg STAND A08 RS LCD monitor PPC stand V type for VESA 75 0 90 degree adjustable hinge and up to 2 5kg capacity VSTAND A07 USB magnetic card reader AFLP 12BMSR U ...

Страница 22: ...LP BRW01 U AFLPBRB01 U VFD customer display green 5x7 dot matrix black white FLP CDB01 AFLP CDW01 12V DC 60W power adapter with bare wire 90 264V AC input 63000 FSP0601AD101C760 RS DC 12 V input 60 W UPS module with 3800mAH 2S2P Li Ion battery VESA 75 AUPS A10 R10 Table 3 2 Optional Items ...

Страница 23: ...IOVU 570M Panel PC Page 15 Chapter 4 4 Installation ...

Страница 24: ...may only be carried out by qualified personnel who are familiar with the associated dangers Air Circulation Make sure there is sufficient air circulation when installing the IOVU 570M The IOVU 570M s cooling vents must not be obstructed by any objects Blocking the vents can cause overheating of the IOVU 570M Leave at least 5 cm of clearance around the IOVU 570M to prevent overheating Grounding The...

Страница 25: ...he IOVU 570M Detailed descriptions of the connectors can be found following the table Connector Type 12 36 V DC bare wire power terminal Terminal Block Ethernet connectors RJ 45 Jack connector RS 232 422 485 Serial connector D sub 9 Male connector USB connectors Dual USB port Table 4 1 External Interface Connectors Figure 4 2 IOVU 570M Peripheral Connectors ...

Страница 26: ...s Figure 4 3 Power Terminal Block 4 3 2 RS 232 422 485 Serial Port This section outlines the usage and setup of the serial port on the rear I O panel 4 3 2 1 Connecting the Serial Port The IOVU 570M has a single female DB 9 connector on the external peripheral interface panel for a serial device Follow the steps below to connect a serial device to the IOVU 570M Step 1 Insert the serial connector I...

Страница 27: ... to the external interface by tightening the two retention screws on either side of the connector Step 0 4 3 2 2 RS 232 422 485 Selection To select RS 232 RS 422 or RS 485 mode please follow the directions below Step 1 Select Start Programs IEI IEI CEUTILITY exe to run IEI_CEUTILITY exe in the SYSTEM folder on the SD CF card ...

Страница 28: ...l port mode setting Change the value in Figure 4 5 to the desired mode setting Step 3 Click Set Step 4 Click Save Registry to save the changes Step 0 4 3 2 3 Pinouts Serial port pinouts are shown below Pin RS 232 RS 422 RS 485 1 DCD RXD DATA 2 RX RXD DATA 3 TX TXD 4 DTR 5 GND GND GND ...

Страница 29: ...r Jumper Setting NOTE A jumper is a metal bridge that is used to close an electrical circuit It consists of two metal pins and a small metal clip with a plastic cover To CLOSE connect the jumper To OPEN leave the jumper off Enables a 120Ω resistor for an RS 485 network Pin Description Open No resistor Closed 120Ω resistor Table 4 4 Serial Port Terminator Settings ...

Страница 30: ...he IOVU 570M Step 1 Insert a USB Series A plug Insert the USB Series A plug of a device into the USB Series A receptacle on the external peripheral interface See Figure 4 7 Step 1 Figure 4 7 USB Connector USB devices connect directly to the USB connectors on the external peripheral connector panel Pin Description Pin Description 1 VCC 5 VCC 2 D1 6 D2 3 D1 7 D2 4 GND 8 GND Table 4 5 USB Connector P...

Страница 31: ...structions below Step 2 Align the connectors Align the RJ 45 connector on the LAN cable with one of the RJ 45 connectors on the IOVU 570M See Figure 4 8 Figure 4 8 LAN Connection Step 3 Insert the LAN cable RJ 45 connector Once aligned gently insert the LAN cable RJ 45 connector into the on board RJ 45 connector Step 0 The Ethernet connector pinouts are shown below PIN DESCRIPTION 1 TPT 2 TPT 3 TP...

Страница 32: ...inked Table 4 7 SPEED LED LINK LED Status Description Status Description GREEN ON 100 MB OFF 10 MB YELLOW ON Linked Flashing Activity Table 4 7 Ethernet Connector LEDs 4 4 Mounting the System WARNING When mounting the flat panel PC onto an arm onto the wall or onto a panel it is better to have more than one person to help with the installation to make sure the panel PC does not fall down and get d...

Страница 33: ...lot holes at the marked locations on the wall for the bracket retention screws Step 4 Align the wall mounting bracket screw holes with the pilot holes Step 5 Secure the mounting bracket to the wall by inserting the retention screws into the four pilot holes and tightening them Figure 4 10 Figure 4 10 Wall mounting Bracket Step 6 Insert the four monitor mounting screws provided in the wall mounting...

Страница 34: ... the monitor downwards until the monitor rests securely in the slotted holes Figure 4 11 Ensure that all four of the mounting screws fit snuggly into their respective slotted holes NOTE In the diagram below the bracket is already installed on the wall Figure 4 11 Chassis Support Screws Step 9 Secure the panel PC by fastening the retention screw of the wall mounting bracket Figure 4 12 Step 9 ...

Страница 35: ...e but do not over tighten Over tightening the retention screws or bolts may cause them to become stripped rendering them useless To mount the IOVU 570M into a panel please follow the steps below Step 10 Select the position on the panel to mount the IOVU 570M Step 11 Cut out a section from the panel that corresponds to the rear panel dimensions of the IOVU 570M Take care that the panel section that...

Страница 36: ...Step 12 Slide the IOVU 570M through the hole until the frame is flush against the panel Step 13 Insert the panel mounting clamps into the pre formed holes along the edges of the chassis behind the frame Figure 4 14 Panel Mounting Clamp Step 14 Tighten the screws that pass through the panel mounting clamps until the plastic caps at the front of all the screws are firmly secured to the panel Figure ...

Страница 37: ...s a separately purchased item Please correctly mount the arm onto the surface it uses as a base To do this refer to the installation documentation that came with the mounting arm NOTE When purchasing the arm please ensure that it is VESA compliant and that the arm has a 75 mm interface pad If the mounting arm is not VESA compliant it cannot be used to support the IOVU 570M Step 16 Once the mountin...

Страница 38: ...ttern To mount the IOVU onto a stand please follow the steps below Step 1 Line up the threaded holes on the monitor rear panel with the screw holes on the monitor stand mounting plate Step 2 Secure the monitor to the stand with the supplied retention screws Figure 4 16 Step 0 Figure 4 16 Stand Mounting 4 5 Software The IOVU 570M comes with a pre installed Windows CE 5 0 or Linux 2 6 x operating sy...

Страница 39: ...ows CE application Built in NET Compact Framework support with related SDK Thin Client Technology Microsoft RDP Remote Desktop Protocol to enable IOVU 570M to access Microsoft Windows based applications installed on Microsoft Terminal Service server Free pre installed utilities for configuring and diagnosing your IOVU 570M Free remote management tools installed in laptop for remotely configuring m...

Страница 40: ...IOVU 570M Panel PC Page 32 Appendix A A Certifications ...

Страница 41: ...RoHS Directive bans the placing on the EU market of new electrical and electronic equipment containing more than agreed levels of lead cadmium mercury hexavalent chromium polybrominated biphenyl PBB and polybrominated diphenyl ether PBDE flame retardants A 2 IP 64 Compliant Front Panel The front panels on all models in the IOVU series have an ingress protection rating IP of 64 IP 64 or greater The...

Страница 42: ...IOVU 570M Panel PC Page 34 Appendix B B Safety Precautions ...

Страница 43: ...alled moved or modified Do not apply voltage levels that exceed the specified voltage range Doing so may cause fire and or an electrical shock Electric shocks can occur if the IOVU 570M chassis is opened when the IOVU 570M is running Do not drop or insert any objects into the ventilation openings of the IOVU 570M If considerable amounts of dust water or fluids enter the IOVU 570M turn off the powe...

Страница 44: ...any electrical component touch any grounded conducting material During the time the electrical component is handled frequently touch any conducting materials that are connected to the ground Use an anti static pad When configuring or working with an electrical component place it on an antic static pad This reduces the possibility of ESD damage Only handle the edges of the electrical component When...

Страница 45: ...citly mentioned in the cleaning tips Below is a list of items to use when cleaning the IOVU 570M Cloth Although paper towels or tissues can be used a soft clean piece of cloth is recommended when cleaning the IOVU 570M Water or rubbing alcohol A cloth moistened with water or rubbing alcohol can be used to clean the IOVU 570M Using solvents The use of solvents is not recommended when cleaning the I...

Страница 46: ...IOVU 570M Panel PC Page 38 Appendix C C Hazardous Materials Disclosure ...

Страница 47: ...resences of small quantities of certain materials in the product and is applicable to China RoHS only A label will be placed on each product to indicate the estimated Environmentally Friendly Use Period EFUP This is an estimate of the number of years that these substances would not leak out or undergo abrupt change This product may contain replaceable sub assemblies components which have a shorter...

Страница 48: ... Board X O O O O X Metal Fasteners X O O O O O Cable Assembly X O O O O X Fan Assembly X O O O O X Power Supply Assemblies X O O O O X Battery O O O O O O O This toxic or hazardous substance is contained in all of the homogeneous materials for the part is below the limit requirement in SJ T11363 2006 X This toxic or hazardous substance is contained in at least one of the homogeneous materials for ...

Страница 49: ...较短的环境友好使用期限的可替换元件 像是电池或灯管 这些元 件将会单独标示出来 有毒有害物质或元素 部件名称 铅 Pb 汞 Hg 镉 Cd 六价铬 CR VI 多溴联苯 PBB 多溴二苯 醚 PBDE 壳体 X O O O O X 显示 X O O O O X 印刷电路板 X O O O O X 金属螺帽 X O O O O O 电缆组装 X O O O O X 风扇组装 X O O O O X 电力供应组装 X O O O O X 电池 O O O O O O O 表示该有毒有害物质在该部件所有物质材料中的含量均在 SJ T11363 2006 标准规定的限量要求以下 X 表示该有毒有害物质至少在该部件的某一均质材料中的含量超出 SJ T11363 2006 标准规定的限量要求 ...

Отзывы: