1.8KW Router User Manual
27
18.Troubleshooting
18.1.
Emergency stop
Fault: On the emergency stop status, click "OK" and the machine restarts.
Solution: This is a function of the machine. You can set the emergency stop
and restart mode in the software parameters. Two types: restart after restarting
the power, and press the “OK” button to restart. The software settings are as
follows:
When machine Alarm error, press keyboard Ctrl+Shift+Alt+M,to change
parameters.
18.2.
Router cannot be started.
Fault: When using the milling cutter in Cutterserver, the milling cutter does not
rotate, and popped error "The milling tool cannot be started".
Solution: Open the computer-management-device manager-USB serial COM
number, which matches the serial port number of the cutter in CutterServer.
18.3.
Router cannot start
Fault: When using the milling tool, the milling tool does not work, and Alarm the
error 53 ,router fault.
Solution: Reconnect the cutter alarm line.
18.4.
Software serial port in dark status
Fault: Under the Win10 system, the software is not connected, and the serial
port is gray.
Solution: Open Computer-Management-Device Manager-Universal Serial Bus
Controller, reconnect the two COM serial ports, match the COM value in the
CutterServer installation directory to the serial port value in the computer
manager, and restart the computer.
In addition, re-plug the serial cable and check the serial port connection in the
DSP board.