3.3. Electric parameter
The power input can be provided only when the device is connected properly. If the device is plugged
in or unplugged while the cable is live (hot plugging), its electronic components will be damaged.
Make sure that the power is turned off when plugging and unplugging the cable.
Poor power supply, too short interval power off and on operation may cause the device cannot work
in a stable and normal status. It is necessary to keep the power input stable. After turning off the
power input, it need to takes more than 2 seconds to turn on the power input again.
Electric parameter
working voltage
DC 12V
–
24V
working current
100mA (12V typical value)
power consumption
1,2W (12V typical value)
relay
DC 30V/1A
3.4. Work environment
work environment parameter
ESD protection
±8kV (air discharge)
±4kV (direct discharge)
working temperature
-20°C - 70°C
storage temperature
-20°C - 70°C
relative humidity
5% - 95% (no condensation, under normal temperature)
ambient light
0-80000Lux (Non direct sunlight)