![iDTRONIC BLUEBOX ADVANT UHF Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/idtronic/bluebox-advant-uhf/bluebox-advant-uhf_manual_3769057033.webp)
B5U033000E
Page 33 of 54
Save Object
Yes
Sub-Index
03h
Description
Time step
Data Type
UNSIGNED8
Access
RW
PDO Mapping
No
Value Range
See value definition
Default Value
05h
Save Object
Yes
3.2.4
RF Tuning
This section provides details on the configurable dynamic power management
parameters of the
BLUEBOX
Only items 5227U with hardware version 2 and firmware version
2.xx integrates the reconfigurable RF carrier leakage canceler
feature and support RF tuning configuration parameters!
The dynamic power management parameters are managed through the OD
2204h.
Value Definition:
Sub-index 00h contains the number of valid object entries within the record. The
number of valid objects entries shall be the number of the general configuration
parameters. Its value is 04h.
Sub-index 01h to 04h contains a configuration parameter. An attempt to change
the value of the configuration parameter to any not supported value shall be
responded with the SDO abort transfer service (abort code: 06090030h). See
the
BLUEBOX
user manual for value definition details.
Parameter
Description
Range
Default
Max Tune
Steps
The maximum runtime RF tune steps. 0 to disable
the runtime RF tuning.
0 … 250
15