Features
1.4
Input / Output
The
LX007 / LX007SR
has 4 built-in input ports and 4 output ports (2 relay outputs and 2 T
TL outputs) which can be used to manipulate a wide variety of controls.
1.5
Time Schedule Setup
You can program up to 10 time schedules and assign one time schedule to each user. Each t
ime schedule has 8 different time zones from Monday-Sunday (7 time zones) and one holid
ay. Each time zone has 5 different time codes so you can program 5 different time codes for
each day. You can also program time schedules for individual inputs and outputs. That is, if
a time schedule for an input device is activated, that input device will be working only durin
g the time assigned by that time code. Each time schedule is linked to one holiday schedule.
1.6
Schedule Setup
Excepting Sunday, you can program 100 holidays to one holiday schedule. Each holiday sche
dule is linked to one time schedule which has a time code for holidays. You can program all
holidays to a holiday schedule and the time code for holidays is programmed to be the holid
ay time zone of time schedule.
Example:
A.
schedule 01 linked to time schedule 01,
schedule 02 linked to time schedule 02
B.
schedule 02 linked to time schedule 01,
schedule 01 linked to time schedule 03
1.7
Forced Door Open Alarm
When the door is opened by force, the door contact sensor will be activated. For this applica
tion, you have to install the door contact sensor and properly set the door contact time and
outputs to the alarm devices. The Forced Door Open Alarm will be generated until the alarm
is disconnected.
1.8
Door Open Timeout Alarm
The Door Open Timeout Alarm will be generated when the door is open for longer than a ce
rtain time limit, even after the door is opened followed by a normal authentication process.
The Overtime Door Open Alarm will continue to ring until the door is closed.
Содержание LX007
Страница 1: ......
Страница 29: ...Installation of Product 8 p 21 1 Wall Mount Unit mm ...
Страница 48: ...Setting Changes 12 p 40 ...
Страница 49: ...p 41 F1 SETUP MENU 1 F1 SETUP MENU ...
Страница 53: ...p 45 F2 SETUP MENU 2 F2 SETUP MENU ...
Страница 91: ...p 83 F10 SETUP MENU 10 5 Module Version The version of the fingerprint module is displayed ...
Страница 104: ...Troubleshooting p 96 If the problem persists please contact service center ...
Страница 107: ...Index 99 ...