IDT ZMOD4410 Скачать руководство пользователя страница 1

 

ZMOD4410 Evaluation Kit User Manual 

 

© 2019 Integrated Device Technology, Inc. 

April 3, 2019 

 

Description 

The ZMOD4410 Evaluation Kit (EVK) is designed for evaluating 

IDT’s ZMOD4410 Gas Sensor Module for TVOC. The total volatile 

organic compounds (TVOC) measurement is one of the indicators 
for indoor air quality (IAQ). In addition, a measurement mode is 

provided to trigger an external device (e.g., fan, ventilation) based 
on the air quality change. 
The  ZMOD4410  Evaluation  Software  allows  Windows

®

-based 

operating systems to communicate with the ZMOD4410 EVK via a 
USB  connection  on  the  user’s  computer,  which  functions  as  a 

master.  The  software  and  additional  related  documentation  is 
available on the IDT website.  
The EVK’s Communication Board (HiCom) handles the interface 

between the user’s computer and the ZMOD4410 module mounted 
on the ZMOD4410 Sensor Board (Daughter Board). Note: Only one 

Communication Board with one Sensor Board can be connected to 
the computer at a time.  
The  ZMOD4410  Evaluation  Kit  uses  an  FTDI  controller  on  the 

Communication  Board  to  handle  the  USB  protocol,  translate 
communications,  and  synchronize  communications  with  the  I2C 

interface. The Sensor Board includes a decoupling capacitor.  
The Communication Board has devices mounted on both sides. 

The components on the top side generate a stable supply voltage. 
A potentiometer can be used to adjust the internal supply voltage 

in  the  typical  range  from  1.7V  to  3.6V.  Alternatively,  the  user’s 

external supply voltage can be used. The intensity of the adjacent 
LED is proportional to the supply voltage.  

Features

 

 

User-friendly EVK expedites configuration and evaluation of 

the ZMOD4410 Gas Sensor 

 

Operates with IDT provided software; either with executable 
ZMOD4410 GUI or alternatively with firmware programming 

examples for Windows and Linux  

 

The modular design of the EVK allows simple connection of 

Sensor Boards for different gas sensor derivatives and easy 

integration with other sensor products via the I2C interface  

 

The required ZMOD4410 Evaluation Software is available for 

download on the IDT website, which also provides background 
information on TVOC, gas sensing, and sensor programming. 

 

Supports different methods of operation, including Low Power  

 

Additional pins to measure power consumption, supply 
voltage, and GPIO trigger for external device 

 

The bill of materials (BOM) and schematics for the ZMOD4410 
Communication Board and Sensor Board are provided at 

www.IDT.com/ZMOD4410-EVK

. 

ZMOD4410-EVK Contents 

 

ZMOD4410 HiCom Communication Board 

 

ZMOD4410 Sensor Board with ZMOD4410 Gas Sensor 

Module  

 

0.5m Type-B USB to Micro-USB Cable  

ZMOD4410 Evaluation Kit 

 

Содержание ZMOD4410

Страница 1: ...cation Board has devices mounted on both sides The components on the top side generate a stable supply voltage A potentiometer can be used to adjust the internal supply voltage in the typical range fr...

Страница 2: ...ARISE BY REASON OF USAGE OF TRADE CUSTOM OR COURSE OF DEALING Restrictions in Use IDT s ZMOD4410 Evaluation Kit consisting of the ZMOD4410 HiCom Communication Board ZMOD4410 Sensor Board and the ZMOD...

Страница 3: ...nd Low Power Operation Mode 8 Figure 5 Analysis Tab for Measurement Mode Standard Operation and Low Power Operation 10 Figure 6 Analysis Tab for Measurement Mode Odor 11 Figure 7 Communication Board S...

Страница 4: ...nts 1GB RAM Hard drive with at least 500MB free space 1 USB port Windows Vista Windows 7 Windows 8 Windows 10 Internet access for initial download of the drivers and software Important Before installi...

Страница 5: ...care to ensure the proper orientation of the Sensor Board as shown on page 1 3 Insert the micro USB cable into the X1 connector on the Communication Board and connect it to a free USB port on the use...

Страница 6: ...MOD4410 Sensor Board AD5 is a GPIO pin that can be controlled via the software in the Odor measurement mode K4 14 pin connector This is the connector for installing the ZMOD4410 Sensor Board on the Co...

Страница 7: ...10 Evaluation Kit User Manual 2019 Integrated Device Technology Inc 7 April 3 2019 Figure 3 Jumper Settings Connections and Test Points on the Communication Board for the Internal or External Supply V...

Страница 8: ...asurements When the start sensor button is clicked the measurement starts running continuously with the given sample time 2 seconds fixed for Standard Operation 5 seconds default for Odor Operation an...

Страница 9: ...path and file name A comment for example Apply test gas can be added to the data entry by adding a string to the Add comment to next measurement field and then clicking the ok button If a measurement...

Страница 10: ...Power Operation For Odor Operation Click on the tab to display the Analysis tab see Figure 6 The Analysis tab shows two plots Algorithmic output signal with indication on trigger activation times AD5...

Страница 11: ...format One sensor will be processed and displayed at a time For Standard Operation and Low Power Operation the default algorithms applied in the Analysis tab calculate gas concentrations for eCO2 and...

Страница 12: ...ialization measurements Algorithm Result for Standard Operation and Low Power Operation After the stabilization measurements the Algorithm Result field shows a colored bar representing the results fro...

Страница 13: ...ZMOD4410 Evaluation Kit User Manual 2019 Integrated Device Technology Inc 13 April 3 2019 3 Schematics Figure 7 Communication Board Schematic Page 1...

Страница 14: ...ZMOD4410 Evaluation Kit User Manual 2019 Integrated Device Technology Inc 14 April 3 2019 Figure 8 Communication Board Schematic Page 2...

Страница 15: ...ZMOD4410 Evaluation Kit User Manual 2019 Integrated Device Technology Inc 15 April 3 2019 Figure 9 Sensor Board Schematic...

Страница 16: ...nF 0603 10 C13 100nF 0603 11 C14 100nF 0603 12 C15 100nF 0603 13 C16 100nF 0603 14 C17 10 F 16V 0805 15 C18 27pF 0603 16 C19 27pF 0603 17 C20 10 F 16V 0805 18 C21 10 F 16V 0805 19 C22 100nF 0603 20 C2...

Страница 17: ...0 42 K4 K2X7 LH 14 43 K5 V_EXT 1X02 44 L1 10 H 1210 45 L2 10 H 1210 46 L3 10 H 1210 47 Modul1 Honeywell480 3652 1 ND DIL8 SMD SOCKEL 48 Q1 12 00MHz QUARZ ABM3 49 R1 1k 0805 50 R2 1k 0805 51 R3 1 6k 08...

Страница 18: ...able 4 Sensor Board BOM Designator Quantity Manufacturer Manufacturer Part Number C1 1 Taiyo Yuden LMK105BJ104KV F U1 1 IDT ZMOD4410 X1 1 Sullins SFH11 PBPC D07 ST BK 5 Board Layout Figure 10 HiCom Co...

Страница 19: ...ZMOD4410 Evaluation Kit User Manual 2019 Integrated Device Technology Inc 19 April 3 2019 Figure 12 Sensor Board Layout Top Layer Figure 13 Sensor Board Layout Bottom Layer...

Страница 20: ...and are not guaranteed to perform the same way when installed in customer products The information contained herein is provided without representation or warranty of any kind whether express or impli...

Отзывы: